SP TOOLS Laser Actuated Tachometer
- Non contact measurement of RPM
- RPM range 2.5–99,999
- Instant and total RPM function
- Memory function
- 50mm–2000mm range with reflective tape
- Accuracy +/- 0.05%
Related products
-
Diagnostic Tools
KLEIN TOOLS Insulation Resistance Tester
- Voltage Tester tests insulation resistance up to 4000MΩ at 125V, 250V, 500V and 1000V DC
- Megohmmeter with test and lock buttons for simple insulation testing
- Warning alarm and high voltage icon for detection of voltage
- Measures up to 1000V AC/DC, resistance and continuity
- Automatic ranging True Root Mean Square (TRMS) technology for increased accuracy
- Backlit display with bar graph, Auto-Power Off, High Voltage, Max/Min and Hold icons
- Low battery indicator with easily replaceable battery and fuse
- Built-in stand and optional magnetic hanger for hands-free operation
- Test verification of conformity to EN61557-1,-2,-4
- CAT IV 600V and CAT III 1000V safety rating
- Includes Right Angle Test Leads and Heavy-Duty Alligator Clip Test Leads
(0 reviews) -
Diagnostic Tools
SP TOOLS CAN OBDII/EOBD Scanner Code Reader
- Designed to work with OBDII compliant vehicles including next generation protocol, Control Area Network (CAN). Operation relies on access being provided by the vehicle manufacturer, for which legislation was introduced in Australia & NZ 2006, USA – 1996, Europe (petrol) 2001, Europe (diesel) 2004.
Note: This model is not compatible with Japanese manufactured vehicles using JOBD protocol. - Reads and clears generic and manufacturer specific diagnostic trouble codes (DTC’s) and turns off check engine light
- Supports multiple trouble code requests: Generic codes, pending codes and manufacturer specific codes
- Code definitions are displayed on unit screen
- Reviews the emission readiness status of OBDII Monitors
- Determines malfunction indicator lamp (MIL) status
- Retrieves VIN (Vehicle Identification No.) on 2002 and newer vehicles that supports Mode 9
- Reviews the live data on unit screen
- Easy to use with one plug in, highly reliable and accurate
- Stand-alone unit with no need for an additional laptop/computer to operate
- Small in size and comfortably fits in the palm of your hand
- Unit updates via internet by USB cable
- Software CD with over 10,000 DTC definitions included
- No batteries needed as the unit is powered via OBD2 cable
(0 reviews) - Designed to work with OBDII compliant vehicles including next generation protocol, Control Area Network (CAN). Operation relies on access being provided by the vehicle manufacturer, for which legislation was introduced in Australia & NZ 2006, USA – 1996, Europe (petrol) 2001, Europe (diesel) 2004.
-
Diagnostic Tools
INSTRUMENT CHOICE WBGT Heat Stress Meter
IC800036Please note: These units do not come with formal calibration certificates, if required please contact us to ensure the correct certificate can be provided.Measure heat stress in the field
Benefits and Features:
15 Second Response Time
Audible Alarm
Adjustable to your WBGT Threshold
Indoor/Outdoor Settings
Tripod ThreadsGovernment organizations such as OSHA have set recommended heat stress limits for various activities. WBGT (Wet Bulb Globe Temperature) provides the most accurate determination of the heat stress index based on the cumulative effect of air temperature, air movement, relative humidity, and radiant heat. WBGT Heat Stress Meter IC800036 is a light-weight meter compact enough to carry anywhere to avoid heat exhaustion in public health, sports, military and industrial activities. Highly accurate readings with a typical response time of only 15 seconds. Provides settings for both indoor and outdoor activity and includes an audible alarm, adjustable to your WBGT threshold. Can be mounted on standard camera tripod (not supplied).
Globe diameter: 40 mm
Meter dim: 255 50 30 mm
Weight: 126 g(0 reviews) -
Diagnostic Tools
INSTRUMENT CHOICE Scarlet Heat Stress Detector
IC-TWL-1SPlease note; These units do not come with formal calibration certificates, if required please contact us to ensure the correct certificate can be provided.Features:– Dash board: Colorful LCD backlight tells you the risk level based on the TWL value. Work-rest schedule and fluid intake are integrated into the display. A countdown timer shows the time remaining before a recommended rest.
– Cup anemometer captures winds from any direction. You do not have to manually decide the wind direction before measuring the wind speed. Compared to the impeller, wind cup is not restricted to the direction of the wind. It considers all the horizontal components of winds that move the anemometer. A silicone pad covers the top of the bearing to prevent it from dust accumulation.– Data Logger : TWL-1S can record data with configurable sampling rate. PC side software helps download the data for further analysis using other analytical tools, and it also synchronizes the date and time of the device with PC.– Optimised Globe: TWL theory considers Mean Radiant Temperature (MRT), the most important parameter governing human energy balance. MRT can be derived from globe temperature (GT) measured by the black-bulb thermometer. The smaller the surface area of the black bulb, the greater the effect of the air temperature and air velocity is, thus causing inaccuracy of the calculation of MRT. Therefore, it needs a modifying formula to adjust it to the standard globe bulb with a diameter of 15 cm. The 7.5 cm globe bulb is the optimal size for a portable based on our research and experiments.– Sensor Protection : Delicate temperature and humidity sensor are well protected by a replaceable polypropylene (PP) filter in a solid shield, exempted the sensors from dust damage and external strike. A silicone pad protects the mechanism of anemometer from dust.Measurement specifications:– Air Temperature (Range): 0-60 C
– Air Temperature (Accuracy): 0.6 C– Globe Bulb Indoor (Range) 0-80 C– Globe Bulb Indoor (Accuracy): 1.0 C (15…40 C); 1.5 C (others)– Globe Bulb Outdoor (Range): 0-80 C– Globe Bulb Outdoor (Accuracy): 1.5 C (15…40 C); 2.0 C (others)– Relative Humidity (Range): 5-95 %rh– Relative Humidity (Accuracy): 3% (at 25 C; 10…90 %rh) 5% (others)– Wind Speed (Range): 0.5 – 10 m/s– Wind Speed (Accuracy): (2% of reading + 0.2) m/sMeter specifications:– Operating range electronics: -1060 C
– Accuracy at 23 5 C: 1.0 %rh / 0.2 K– Power supply / consumption: 4 AAA 3V battery, power supply 4 mA consumption without lighting– Probe protection: Polypropylene plastic cage– Calibration / adjustment: Scarlet calibration kit– Measurement interval: 2 seconds– Back-light: with Back-light– Alarm indicators: Yes– Battery indicator: Low Batt. Display– Software: Scarlet TWLIT– Risk level indicator: Yes. 3 color LCD backlight: red (risk), yellow (med), green (safe)– Data logger: Yes. Min data rate 10 min, 2,000 data.– Connection Interface: Mini USB (UART)– Enclosure material: ABS(0 reviews)