KLEIN TOOLS Digital Multimeter, Manual-Ranging, 600
- Multimeter measures up to 600V AC/DC voltage, 10A DC current, 2 MOhms resistance, continuity, batteries and diodes
- Lead Alert protection with LEDs for test lead placement
- Easy-to-view backlit display for low light environments
- Low battery indicator and easily accessible battery and fuse compartment
- Durable meter built to withstand a 6.6′ (2 m) drop
- Includes test leads, batteries and user manual
- CAT III 600 V safety rating
- For use in basic and controlled electromagnetic environments, such as residential, business and light-industrial locations
SKU: MM325
Categories: Diagnostic Tools, Diagnostic Tools, Diagnostic Tools, KLEIN TOOLS
Related products
-
Diagnostic Tools
SP TOOLS Videoscope – Smart Tool Attachment – Suits SP61170
TURN YOUR SP SMART TOOL INTO A VIDEOSCOPE
With forward and side facing cameras this probe allows technicians to quickly and easily inspect engine and vehicle components, without major disassembly.
FEATURES
- Dimmable front & Side Camera Lights
- Camera Diameter: 5.5mm
- View Angle: 60°
- Resolution: 1280x720Frame Rate: 30fps
- Flexible Camera Tube Length: 1m
(0 reviews) -
Diagnostic Tools
INSTRUMENT CHOICE Scarlet Heat Stress Detector
IC-TWL-1SPlease note; These units do not come with formal calibration certificates, if required please contact us to ensure the correct certificate can be provided.Features:– Dash board: Colorful LCD backlight tells you the risk level based on the TWL value. Work-rest schedule and fluid intake are integrated into the display. A countdown timer shows the time remaining before a recommended rest.
– Cup anemometer captures winds from any direction. You do not have to manually decide the wind direction before measuring the wind speed. Compared to the impeller, wind cup is not restricted to the direction of the wind. It considers all the horizontal components of winds that move the anemometer. A silicone pad covers the top of the bearing to prevent it from dust accumulation.– Data Logger : TWL-1S can record data with configurable sampling rate. PC side software helps download the data for further analysis using other analytical tools, and it also synchronizes the date and time of the device with PC.– Optimised Globe: TWL theory considers Mean Radiant Temperature (MRT), the most important parameter governing human energy balance. MRT can be derived from globe temperature (GT) measured by the black-bulb thermometer. The smaller the surface area of the black bulb, the greater the effect of the air temperature and air velocity is, thus causing inaccuracy of the calculation of MRT. Therefore, it needs a modifying formula to adjust it to the standard globe bulb with a diameter of 15 cm. The 7.5 cm globe bulb is the optimal size for a portable based on our research and experiments.– Sensor Protection : Delicate temperature and humidity sensor are well protected by a replaceable polypropylene (PP) filter in a solid shield, exempted the sensors from dust damage and external strike. A silicone pad protects the mechanism of anemometer from dust.Measurement specifications:– Air Temperature (Range): 0-60 C
– Air Temperature (Accuracy): 0.6 C– Globe Bulb Indoor (Range) 0-80 C– Globe Bulb Indoor (Accuracy): 1.0 C (15…40 C); 1.5 C (others)– Globe Bulb Outdoor (Range): 0-80 C– Globe Bulb Outdoor (Accuracy): 1.5 C (15…40 C); 2.0 C (others)– Relative Humidity (Range): 5-95 %rh– Relative Humidity (Accuracy): 3% (at 25 C; 10…90 %rh) 5% (others)– Wind Speed (Range): 0.5 – 10 m/s– Wind Speed (Accuracy): (2% of reading + 0.2) m/sMeter specifications:– Operating range electronics: -1060 C
– Accuracy at 23 5 C: 1.0 %rh / 0.2 K– Power supply / consumption: 4 AAA 3V battery, power supply 4 mA consumption without lighting– Probe protection: Polypropylene plastic cage– Calibration / adjustment: Scarlet calibration kit– Measurement interval: 2 seconds– Back-light: with Back-light– Alarm indicators: Yes– Battery indicator: Low Batt. Display– Software: Scarlet TWLIT– Risk level indicator: Yes. 3 color LCD backlight: red (risk), yellow (med), green (safe)– Data logger: Yes. Min data rate 10 min, 2,000 data.– Connection Interface: Mini USB (UART)– Enclosure material: ABS(0 reviews) -
Diagnostic Tools
KLEIN TOOLS Digital Multimeter Electrical Test Kit
- Digital Multimeter measures up to 600V AC/DC voltage, 10A DC current and 2 ohm resistance
- Meter also test batteries, diodes and continuity
- Voltage Tester NCVT-3P has dual-range capabilities to detect from 12 to 1000V AC or 70 to 1000V AC for a broad variety of low-voltage or standard voltage applications
- Bright torch illuminates work area and may be used independent of the NCVT-3P voltage detection function
- ET45 tests AC voltages from 28V to 240V AC at four useful levels aligned with commonly used residential voltages, and DC voltages from 32V to 330V at four common levels
- Built-in test lead holders on back of ET45 hold the leads in one of two positions: one so that they are spaced correctly to test tamper-resistant US-style outlets; and the other for the convenient storage of the test leads
- RT210 detects the most common wiring problems in standard and GFCI receptacles including open ground, reverse polarity, open hot, open neutral and hot/ground reversed
- Receptacle tester works on GFCI outlets and confirms the operation of the ground fault protective device
(0 reviews) -
Diagnostic Tools
KLEIN TOOLS Slim Digital Multimeter, TRMS Auto-Ranging, 600V, Temp
- Multimeter with automatic ranging True Root Mean Square (TRMS) technology for increased accuracy
- Measures up to 600V AC/DC voltage, 10A AC/DC current and 50 MΩ resistance, continuity, temperature, capacitance, frequency, duty-cycle and test diodes
- High visibility, reverse contrast display with automatic backlight adjustment
- Lead Alert protection with LEDs for test lead placement
- Slim profile allows multimeter to conveniently fit into most pockets
- Low battery indicator and easily accessible battery and fuse compartment
- Durable meter built to withstand a 6.6′ (2 m) drop
- Includes carrying pouch, safety rated CAT III 1000V/CAT IV 600V test leads, thermocouple with adapter and 2 x AAA batteries
- CAT III 600 V safety rating
- For use in basic and controlled electromagnetic environments, such as residential, business and light-industrial locations
(0 reviews)






