FLUKE Calibration 9102S Handheld Dry-Well
- Temperature ranges from –10°C to 375°C.
- Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
- Equipped with an RS-232 interface for connectivity.
Related products
-
Temperature Calibrators
FLUKE Calibration 1502A/1504 Thermometer Readout
Precision thermometer readouts for laboratory and field use
1502A Tweener PRT Readout
The Fluke Calibration 1502A Tweener offers precision temperature measurement with:
- Accuracy up to ±0.006 °C
- Resolution of 0.001 °C across the entire range
- Compatibility with 100-ohm, 25-ohm, and 10-ohm RTD probes
- Smallest unit in its class, ideal for field or bench use
- Optional 9320A Battery Pack for full portability
Advanced Features
- Programmable to match a probe’s constants for maximum linearity and accuracy
- Displays temperature in °C, °F, K, or resistance in ohms
- Reads standard industrial IEC-751 / “385 ALPHA” RTDs with no programming required
- Accepts ITS-90 subranges 4 and 6–11, with formulas built into firmware
- Calibration is done digitally via front-panel—no need to open the device
- Comes with RS-232 interface; optional IEEE-488 interface available
1504 Tweener Thermistor Readout
Need higher precision in a narrower temperature range? The Model 1504 Tweener offers:
- Accuracy up to ±0.002 °C
- Resolution of 0.0001 °C
- Designed specifically for thermistors—more robust, shock-resistant sensors with faster response times
- Ideal for applications requiring high sensitivity and reliability in limited temperature spans
Calibration and Probe Integration
- Each Tweener and its compatible probe (sold separately) include individual calibration reports
- System data is available upon request at two or more temperatures for high-precision needs (Calibration Model 1929-X)
- Users can calculate system accuracy using individual device specifications—no need to purchase system-level data unless required
Software Compatibility
Enhance your workflow with Fluke software tools:
- 9934 LogWare: Real-time data acquisition, graphing, and analysis
- MET/TEMP II: Use Tweeners as reference thermometers for automated calibrations
Optional Battery Pack
Take your Tweener on the road with the 9320A Battery Pack:
- Provides up to 36 hours of portable operation between charges
- Perfect for fieldwork or locations without direct power access
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 9009 Dual-Well Dry-Well
Two blocks. One portable calibrator. Full temperature coverage.
Dual Independent Temperature Blocks
The Fluke Calibration 9009 combines two independently controlled temperature blocks into one compact, rugged system:
- Hot block range: 50 °C to 350 °C
- Cold block range: –15 °C to 110 °C
- Each block is powered by a precision Hart Scientific temperature controller—not off-the-shelf components, but industry-leading technology from the world’s top temperature calibration experts.
Flexible Multi-Probe Calibration
Each block includes two wells with removable inserts, giving you unmatched flexibility:
- Calibrate up to four probes simultaneously
- Use two probes with an external reference thermometer (e.g., Hart 1521 LLK)
- Perform quick zero/span checks for transmitter calibration with both blocks in use
Portable and Field-Ready
The 9009 is built for portability and field durability:
- Housed in a rugged Pelican™ case—airtight, watertight, and impact-resistant
- Weighs only 10 lbs (4.5 kg), compact and easy to carry
- Internal storage holds the power cord and four extra inserts
- Inserts available for sensor sizes from 1/16” (1.6 mm) to 7/16” (11.1 mm)
This system is truly ready to go wherever your work takes you.
Reliable Accuracy and Stability
Performance you expect from a Fluke/Hart Scientific source:
Block Display Accuracy Stability Cold ±0.2 °C ±0.05 °C Hot ±0.6 °C ±0.05 °C NIST-traceable calibration certificate included for both blocks.
PC Connectivity and Automation
- RS-232 interface included for temperature monitoring and control via PC
- Fully compatible with MET/TEMP II software for automated calibration of RTDs, thermocouples, and thermistors
The Complete Field Calibration Package
With the Fluke 9009 Dual-Well Dry-Well, you get:
- Two independent blocks
- Full temperature coverage from –15 °C to 350 °C
- True field portability in a compact, durable case
- Flexibility for multiple sensors and calibration modes
- Built-in automation and PC integration
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 6102/7102/7103 Micro-Bath
Portable and extremely stable
Need portability and extreme stability? Fluke Calibration Micro-Baths have both. We invented the Micro-Bath. And, while many have tried to duplicate it, none of them use proprietary Fluke Calibration controllers, so none of them deliver performance like a Fluke Calibration bath. Micro-Baths can be used anywhere for any type of sensor. The 6102 weighs less than 4.5 kg (10 lb.), with the fluid. It’s lighter and smaller than most dry-wells, has a spill-proof lid, and is easier to carry than your lunch. You can take it where you need to go without carts or excessive effort. Micro-Baths can even be transported with the fluid in them.
Wherever you go with your Micro-Bath, you can count on its performance. Each model is stable to ±0.03 °C or better, depending on the fluid you use. Uniformity is ±0.02 °C or better for low uncertainties using a reference thermometer. Display accuracy has been improved to ±0.25 °C for quick calibrations without a reference thermometer. In short, you get the stability and precision of a liquid bath in a dry-well-sized package. Don’t be fooled by competitors who pour oil into a dry-well and call it a bath. Micro-Baths are maximized for true fluid-bath performance.
With a 48 mm (1.9-inch) diameter, 140 mm (5.5-inch) deep tank, a Micro-Bath can calibrate any type of sensor including short, square, or odd-shaped sensors. The problems of fit and immersion are virtually eliminated by using a fluid medium rather than a dry-block calibrator. Micro-Baths are perfect for liquid-in-glass and bimetal thermometers.
The 6102 has a temperature range from 35 °C to 200 °C, the 7102 covers –5 °C to 125 °C, and the 7103 extends from –30 °C to 125 °C. Stability, uniformity, and accuracy specifications cover the entire range for each bath, not just the best temperature.
All Micro-Baths have RS-232 ports and can be used with MET/TEMP II software (described on page 81). Also included are contacts to calibrate a thermal switch, eight set-point memory storage, ramp-rate adjust, and over-temperature safety cutout.
You may have noticed we haven’t touted our CFC-free refrigeration. Yes, cold Micro-Baths are CFC-free, and also compressor-free. That’s right—no heavy, noisy compressor to lug around. We achieve our temperature range and stability with only one moving part. This means more durability and less weight. Fluke Calibration manufactures and sells temperature calibration baths of every size and shape, and now we have the smallest and lightest baths in the industry to go with the dozens of other models we make.
Look at the specs, price, and value of these portable instruments and you’ll know why Fluke Calibration is the number-one company in this business.
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 9103/9140 Field Dry-Well
Portable, fast, and accurate temperature sources for on-site calibration
Exceptional Performance in a Compact Design
The Fluke 9103 and 9140 Field Dry-Wells outperform the competition in nearly every category—performance, size, weight, ease of use, calibration simplicity, software integration, and price.
Each unit features:
- Adjustable heating and cooling rates via the front panel
- Thermal switch actuation testing
- Multiple-hole inserts for compatibility with a wide range of probe sizes
Fast Calibration with Minimal Downtime
- Units are easy to calibrate without opening the case, reducing maintenance costs and downtime
- All units include a NIST-traceable calibration certificate at no additional charge
- Factory-tested for accuracy and reliability before shipment
Software Integration
Fluke’s Interface-it software supports:
- Set-point and ramp rate control
- Real-time temperature logging
- Electronic strip chart creation
- Thermal switch test automation with data collection
- Windows-based interface with intuitive graphical controls
Whether you need basic control or full automation, Fluke has a software solution ready.
Fluke 9103 – Low-Temperature Field Dry-Well
- Temperature Range: Down to –25 °C (actual, not below ambient)
- Stability: ±0.02 °C
- Display Accuracy: ±0.25 °C across full range
- Speed:
- Reaches 0 °C in 8 minutes
- Reaches 100 °C in 6 minutes
Key Advantage:
Many competitors advertise –45 °C below ambient, which only reaches around –20 °C. The 9103 delivers a true –25 °C in standard room conditions—no walk-in freezer required.
Insert Options:
Choose from four removable inserts to suit your calibration needs:
- Insert A: One well each from 1/16” to 1/2”
- Insert B: Two wells each of 3/8”, 1/4”, and 3/16” (ideal for comparison calibrations)
- Insert C: Six 1/4” wells for multiple probe calibrations
- Insert D: Three pairs of metric-sized wells
Fluke 9140 – Mid-Temperature Field Dry-Well
- Temperature Range: 35 °C to 350 °C
- Stability: ±0.05 °C or better
- Uniformity:
- 0.1 °C in small-diameter wells
- 0.4 °C in largest-diameter wells
- Speed: Reaches max temperature in 12 minutes
- Size: Weighs only 6 lbs, easily portable with one hand
- Display Accuracy: ±0.5 °C
For improved calibration accuracy, use an external thermometer alongside the built-in display.
Insert Options:
Three removable inserts available to accommodate various probe sizes.
Why Choose the 9103 or 9140?
Model Temperature Range Stability Display Accuracy Key Benefits 9103 –25 °C to 110+ °C ±0.02 °C ±0.25 °C True sub-ambient performance without freezer 9140 35 °C to 350 °C ±0.05 °C ±0.5 °C Light, fast, and ideal for field portability Both models are:
- Reliable for industrial and lab environments
- Versatile with multiple insert options
- Backed by Fluke’s proven calibration technology
(0 reviews)