FLUKE 729 Automatic Pressure Calibrator
- Automatic pressure generation and regulation to 300 psi
- Configure procedures for pressure transmitters and switches
- Measure, source, and simulate 4 to 20 mA signals
- Troubleshoot and calibrate HART smart transmitters
- Automatically document test results
Related products
-
Pressure Calibrators
FLUKE Calibration P3200 Hydraulic Deadweight Tester
The P3200 models are available in single or dual piston formats for increased operating ranges. Units can be supplied in psi, bar, kgf/cm², and MPa. This robust instrument is highly accurate, quick and easy to use. Units feature a built-in priming pump for large volume applications, piston flotation indicators and a high quality screw press for fine pressure control.
Options
PressCal software for pressure calculations and certificate generation
Operating principle
Deadweight testers are the high performance pressure standard for pressure measurement. Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated weight masses (Force) are loaded on the piston (Area), which rises freely within its cylinder. These weights balance the upward force created by the pressure within the system. The pressure is measured when placed on a correctly spinning and floating piston. The total pressure measured is the summation of the weights plus the piston weight carrier assembly.
Instrument base
There are three basic variations in the hydraulic offering; single low pressure, single high pressure and dual piston models. Pressure is generated and controlled by means of a high quality screw press located on the front of the tester. A built-in hand pump is included as standard for all hydraulic models to prime the system and accommodate large volume requirements.
Piston/cylinder assemblies
The piston/cylinder assembly is the heart of each deadweight tester. They are manufactured from materials that provide stability, durability, and low thermal coefficients and distortion. Our experience and knowledge of piston/cylinder production and calibration ensure the precision and performance required for today’s demanding calibration requirements.
Weight masses
Standard weight masses are series 3 nonmagnetic austenitic stainless steel. Each mass is marked with the serial number of the instrument and the nominal pressure value relative to the high or low-pressure piston, when applicable. Optional fractional weights are stainless steel and/or solution heat treated aluminum.
Gravity correction
Gravity varies significantly with geographical location and this variation has a direct effect on the force of the weights and the accuracy of the deadweight tester. Each instrument can be calibrated to local gravity at no extra cost. If unspecified, instruments will be calibrated to Standard Gravity at 980.665 cm/s2.
(0 reviews) -
Pressure Calibrators
FLUKE 700G Pressure Gauge Calibrator
Portable, Precise, and Built for Field Calibration
Your Go-To Solution for Field Pressure Calibration
The Fluke 700G Series Pressure Gauge Calibrators are engineered specifically for field professionals who need rugged, accurate, and easy-to-use pressure measurement on the job. With a reputation for reliability and performance, the Fluke 700G is the ideal Fluke pressure gauge for demanding calibration and test applications.
Key Features of the Fluke 700G
- Extensive Pressure Range – Choose from 23 different models, covering ±10 inH2O/20 mbar up to 10,000 psi/690 bar. Whatever your field calibration needs, there’s a Fluke 700G pressure gauge that fits.
- High Accuracy – Standard accuracy is 0.05% of full scale. Reference class models deliver an impressive 0.04% of reading measurement accuracy, ensuring you always meet the most stringent requirements.
- Pressure Data Logging – Store up to 8,493 pressure measurements for later review. Use the 700G/TRACK software to upload, analyze, and report results right from your PC.
- Rugged Field Design – Fluke 700G pressure gauges are housed in a sealed IP67 enclosure and come with a protective holster. They are certified as intrinsically safe (CSA: Class 1, Div2, Groups A-D and ATEX: II 3 G Ex ic IIB T6 Gc), so you can work safely in hazardous or explosive environments.
- Long-Term Reliability – Every Fluke 700G pressure gauge is backed by a standard 3-year warranty for your peace of mind.
Simple, Complete Pressure Calibration—No Compromises
- Effortless Operation – Power on, connect to your pressure device, and read measurements instantly. No complex menus or setup—just fast, accurate pressure calibration in the field.
- Complete Solution with Pump Kits – Pair your Fluke 700G pressure gauge with the Fluke 700PTPK pneumatic or 700HTPK hydraulic pump kits for a complete sourcing and measurement solution. Premium pump kits (700PTPK2 and 700HTPK2) feature easy, no-tools-required connections for both the gauge and device under test.
- Versatile Calibration – Calibrate to 600 psi (20 bar) with the 700PTPK or 700PTPK2 pneumatic pump kit. Handle higher pressures using compatible hydraulic pump solutions.
Built for Field Professionals
- Portable and Lightweight – Take your Fluke pressure gauge anywhere. Designed for durability and ease of use in the harshest environments.
- Safe and Certified – Intrinsically safe certifications let you work confidently in classified areas where explosive gases may be present.
- Easy Connectivity – Premium kits provide “no tools required” setup for fast and secure calibration in the field.
Trust the Fluke 700G Series Pressure Gauge Calibrators for unmatched performance, ruggedness, and reliability. When accuracy and efficiency matter most, choose the Fluke 700G—your field calibration solution.
(0 reviews) -
Pressure Calibrators
FLUKE 750P Series Pressure Modules
Fluke 750P Series Pressure Modules will turn your Fluke multifunction calibrator into a full-fledged pressure calibrator. These flexible modules not only work with multifunction calibrators like the 725, 726 or 750 Series Calibrators but also extend the measurement range of Fluke pressure calibrators. Since the pressure modules are calibrated independently, they can be swapped from one calibrator to another without a loss of accuracy or traceability.
Measuring pressure with Fluke 750P Series Pressure modules is as easy as connecting the module to a pressure source or hand pump, connecting the pressure module cable to the calibrator and then applying pressure from the pressure source. At the touch of a button the measured pressure is displayed digitally on the calibrator in up to 11 different engineering units quickly giving you the data you need. And, with “no tools required” connectors you don’t even need to reach for a wrench to make connections.
When used with the 750 Series Documenting Process Calibrators pressure readings can even be date/time stamped and stored in documented calibration records for later retrieval. This saves time, eliminates errors, and supports compliance with quality standards and regulations.
A complete family of pressure modules
With over 50 pressure modules covering pressure calibration and measurement workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar) finding a model to meet the needs of your specific application is easier than ever. All modules include NPT, metric (BSP) and M20 adapters.
Choose from:
- Differential modules
- Gage modules
- High pressure modules
- Absolute modules
- Vacuum modules
- Dual range modules
- Reference modules
- Intrinsically safe modules
With more than 50 pressure modules to choose from, some of the more popular modules include:
- Fluke 750P00
- Fluke 750P02
- Fluke 750PD2
- Fluke 750P03
- Fluke 750P05
- Fluke 750P06
- Fluke 750P29
Click the Models tab above for a full list of pressure modules.
Designed to go where you work
Pressure instruments are often installed in harsh, hard to reach locations, so you need test tools that handle rough service. 750P Series Pressure Modules feature a rugged protective boot that guards the module against shock and seals against dirt and dust, if you accidently drop them, there’s no need to worry. The 750P series modules are also specified across a broad temperature range. Though more accurate across a narrower temperature range if used indoors, these modules are designed and specified to deliver traceable pressure measurements in environments from -10 °C to +50 °C.
(0 reviews) -
Pressure Calibrators
FLUKE Calibration P3100 Hydraulic Deadweight Testers
The P3100 models are available in single or dual piston format. Unit can be supplied in psi, bar, kgf/cm², and MPa. This robust instrument is highly accurate, quick and easy to use. Units feature a built-in priming pump for large volume applications, piston flotation indicators and a high quality screw press for fine pressure control.
Operating principle
Deadweight testers are the high performance pressure standards for pressure measurement. Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated weight masses (Force) are loaded on the piston (Area), which rises freely within its cylinder. These weights balance the upward force created by the pressure within the system. The pressure is measured when placed on a correctly spinning and floating piston. The total pressure measured is the summation of the weights plus the piston weight carrier assembly.Instrument base
There are three basic variations in the hydraulic offering; single low pressure, single high pressure and dual piston models. Pressure is generated and controlled by means of a high quality screw press located on the front of the tester. A built-in hand pump is included as standard for all hydraulic models to prime the system and accommodate large volume requirements.
Piston/cylinder assemblies
The piston/cylinder assembly is the heart of each deadweight tester. They are manufactured from materials that provide stability, durability, and low thermal coefficients and distortion. Our experience and knowledge of piston/cylinder production and calibration ensure the precision and performance required for today’s demanding calibration requirements.
Weight masses
Standard weight masses are series 3 nonmagnetic austenitic stainless steel. Each mass is marked with the serial number of the instrument and the nominal pressure value relative to the high or low-pressure piston, when applicable. Optional fractional weights are stainless steel and/or solution heat treated aluminum.
Gravity correction
Gravity varies significantly with geographical location and this variation has a direct effect on the force of the weights and the accuracy of the deadweight tester. Each instrument can be calibrated to local gravity at no extra cost. If unspecified, instruments will be calibrated to Standard Gravity at 980.665 cm/s2.(0 reviews)