FLUKE 718 Pressure Calibrator
- Pressure Source and mA Measurement to calibrate pressure devices
- Built-in pump for sourcing pressure to 300 PSI
- Easy-to-clean, field-serviceable, integrated pressure pump
- Built-in switch test for calibrating pressure switches
- Extend pressure capabilities by using Fluke 750P pressure modules
Related products
-
Pressure Calibrators
FLUKE 719 Pressure Calibrator
Calibrate pressure with one hand using the Fluke 719 Electric Pressure Calibrator
Forget the hassle of hand pumping. Now you can calibrate and test pressure devices quickly and easily with one hand, saving valuable time. With the innovative, built-in electric pump, the Fluke 719 Electric Pressure Calibrator provides pressure calibration at your fingertips!
Use the programmable pump limit settings to eliminate over-pressurization, and to set “pump to” pressure values. The unique cleanout port design reduces pump failures, and makes the 719 easy to clean without repair. The compact, lightweight form, combined with one-handed calibration, makes this pressure calibrator the ideal tool for busy process professionals.
The Fluke 719 delivers pressure calibration made easy, by a name you know and trust for all your process calibration needs.
Other useful features:
- Simulates mA signals to troubleshoot 4-20 mA loops
- Powers transmitters during test using 24 V loop supply
- Comes with three-year warranty for calibrator
- Provides variable release rate bleed valve for easy pressure adjustment
- Offers ideal performance for high accuracy transmitter calibration
- Offers a programmable pressure calibrator pump limit that:
- Eliminates over-pressurization
- Allows the user to program target pressures for pumping
- Tests pressure switches easily with switch test function
- Provides extended pressure measurement range with any of 50 750P series Pressure Modules
- Pump cleanout ports to reduce pump failures from moisture and fluid damage
(0 reviews) -
Pressure Calibrators
FLUKE 729 Pro Automatic Pressure Calibrator
Portable automatic pressure calibrator simplifies pressure calibration
The Fluke 729Pro Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure can be a time-consuming task, but the 729Pro makes it easier than ever with an internal electric pump that provides automatic pressure generation and regulation in an in an easy-to-use, rugged, portable package.
Automatic pressure generation and control
The 729Pro allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. With plug-in replaceable pressure control modules and pressure generation and regulation up to 1000 psi (70bar, 7000 kPa). Then, internal fine adjustment control automatically stabilizes the pressure at the requested value. You can also fill in a test template and the 729Pro will automatically pump to and document a multiple-point pressure calibration test at the touch of a button.
Easy calibration documentation
The Fluke 729Pro can automatically test multiple pressure test points and automatically document the results. The 729Pro does the work for you by documenting and flagging out-of-tolerance test results in red on the graphical display for:
- Applied pressure
- Measured mA, mV, or digital PV
- % error for each test point
Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data.
HART communication
Built-in HART communication capabilities enable HART transmitter mA adjustments, HART configuration, and the ability to adjust to applied 0% and 100% values. You can also configure various tasks such as changing a transmitter tag, measurement units, and ranging. Other supported HART commands include setting fixed mA outputs for troubleshooting, read device configuration, and variables and read device diagnostics.
Rugged, portable design
The 729Pro is tested and warranted to withstand a 1-meter drop test so it is ready for field instrumentation calibration work. With two models 4M up to 600 psi (40 bar, 4000 kPa), and 7M up to 1000 psi (70 bar, 7000 kPa) to choose from, the Fluke 729Pro Automatic Pressure Calibrators are designed to perform when and where you need them. A standard semi-rigid carrying case designed for field work, with room in the case to store test hoses, fittings, test leads, and small hand tools means it’s easy to carry everything needed for field pressure calibrations.
For greater accuracy and resolution on low pressure calibrations, the Fluke 729Pro allows you to select and insert one of 6 Fluke Pressure Modules to expand the pressure range between 0-600 psi (40 bar, 4000 kPa).
(0 reviews) -
Pressure Calibrators
FLUKE 700PRV-1 Pressure Relief Valve Kit
The Fluke 700PRV-1 consists of a relief valve settable from 725 to 5800 PSI (50 to 200 bar) to be used with the 700HTP-1 Hydraulic Test Pump. The 1/8” NPT male thread to fits directly into the Fluke 700HTP-1 pressure pump.
To be used with the 700HTP-1 Hydraulic Test Pump. The 700PRV uses a multi-turn adjustment screw to set preload on internal disc springs. This relief valve will protect the most commonly used Fluke pressure modules and pressure instruments from damage due to accidental over-pressurization.
(0 reviews) -
Pressure Calibrators
FLUKE 719Pro Electric Pressure Calibrator
- Unique integrated electric pump for one handed pressure calibration
- Test pressure switches easily with easy-to-use switch test function
- Precision pressure adjust vernier for easy and accurate pressure calibration
- Ideal accuracy and performance (0.025%) for reference class transmitter calibration
- 30 psi, 150 psi and 300 psi pressure ranges
- Programmable pressure calibrator pump limit:
- Eliminates over-pressurization
- Allows the user to program target pressures for pumping
- Extended pressure measurement range with any of 29 750P Pressure Modules
- Pump cleanout ports reduce pump failures from moisture and fluid damage
- Fluid trap included with the unit to mitigate chance of fluid damage in at-risk applications
- Precision temperature measurement with optional RTD probe
(0 reviews)