FLUKE 700PRV-1 Pressure Relief Valve Kit
The Fluke 700PRV-1 consists of a relief valve settable from 725 to 5800 PSI (50 to 200 bar) to be used with the 700HTP-1 Hydraulic Test Pump. The 1/8” NPT male thread to fits directly into the Fluke 700HTP-1 pressure pump.
To be used with the 700HTP-1 Hydraulic Test Pump. The 700PRV uses a multi-turn adjustment screw to set preload on internal disc springs. This relief valve will protect the most commonly used Fluke pressure modules and pressure instruments from damage due to accidental over-pressurization.
Related products
-
Pressure Calibrators
FLUKE 719 Pressure Calibrator
Calibrate pressure with one hand using the Fluke 719 Electric Pressure Calibrator
Forget the hassle of hand pumping. Now you can calibrate and test pressure devices quickly and easily with one hand, saving valuable time. With the innovative, built-in electric pump, the Fluke 719 Electric Pressure Calibrator provides pressure calibration at your fingertips!
Use the programmable pump limit settings to eliminate over-pressurization, and to set “pump to” pressure values. The unique cleanout port design reduces pump failures, and makes the 719 easy to clean without repair. The compact, lightweight form, combined with one-handed calibration, makes this pressure calibrator the ideal tool for busy process professionals.
The Fluke 719 delivers pressure calibration made easy, by a name you know and trust for all your process calibration needs.
Other useful features:
- Simulates mA signals to troubleshoot 4-20 mA loops
- Powers transmitters during test using 24 V loop supply
- Comes with three-year warranty for calibrator
- Provides variable release rate bleed valve for easy pressure adjustment
- Offers ideal performance for high accuracy transmitter calibration
- Offers a programmable pressure calibrator pump limit that:
- Eliminates over-pressurization
- Allows the user to program target pressures for pumping
- Tests pressure switches easily with switch test function
- Provides extended pressure measurement range with any of 50 750P series Pressure Modules
- Pump cleanout ports to reduce pump failures from moisture and fluid damage
(0 reviews) -
Pressure Calibrators
FLUKE 730G Digital Pressure Calibrator
- Pressure measurement from ±10 inH2O/2.5 kPa to 10000 psi/69 MPa
- Four absolute pressure measurement ranges: 15 PSIA (103 kPa), 30 PSIA (207 kPa), 100 PSIA (690 kPa), 300 PSIA (2 MPa)
- Pressure measurement accuracy 0.05% of full scale, 0.02% optional
- Current measurement range: 0-24mA
- Voltage measurement range: 0-30VDC
- 0.01% current and voltage accuracy
- Powerful HART communication, supports HART 7
- 24V loop power, no external power supply needed
- Lithium battery life: 25 hours continuously (without 24 V loop power), or 8 hours continuously (24 V loop power)
- Storage up to 128 sets of calibration data
- Ingress protection: IP54
- 1-meter drop test
- Three-year warranty
(0 reviews) -
Pressure Calibrators
FLUKE Calibration P3100 Hydraulic Deadweight Testers
The P3100 models are available in single or dual piston format. Unit can be supplied in psi, bar, kgf/cm², and MPa. This robust instrument is highly accurate, quick and easy to use. Units feature a built-in priming pump for large volume applications, piston flotation indicators and a high quality screw press for fine pressure control.
Operating principle
Deadweight testers are the high performance pressure standards for pressure measurement. Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated weight masses (Force) are loaded on the piston (Area), which rises freely within its cylinder. These weights balance the upward force created by the pressure within the system. The pressure is measured when placed on a correctly spinning and floating piston. The total pressure measured is the summation of the weights plus the piston weight carrier assembly.Instrument base
There are three basic variations in the hydraulic offering; single low pressure, single high pressure and dual piston models. Pressure is generated and controlled by means of a high quality screw press located on the front of the tester. A built-in hand pump is included as standard for all hydraulic models to prime the system and accommodate large volume requirements.
Piston/cylinder assemblies
The piston/cylinder assembly is the heart of each deadweight tester. They are manufactured from materials that provide stability, durability, and low thermal coefficients and distortion. Our experience and knowledge of piston/cylinder production and calibration ensure the precision and performance required for today’s demanding calibration requirements.
Weight masses
Standard weight masses are series 3 nonmagnetic austenitic stainless steel. Each mass is marked with the serial number of the instrument and the nominal pressure value relative to the high or low-pressure piston, when applicable. Optional fractional weights are stainless steel and/or solution heat treated aluminum.
Gravity correction
Gravity varies significantly with geographical location and this variation has a direct effect on the force of the weights and the accuracy of the deadweight tester. Each instrument can be calibrated to local gravity at no extra cost. If unspecified, instruments will be calibrated to Standard Gravity at 980.665 cm/s2.(0 reviews) -
Pressure Calibrators
FLUKE 750P Series Pressure Modules
Fluke 750P Series Pressure Modules will turn your Fluke multifunction calibrator into a full-fledged pressure calibrator. These flexible modules not only work with multifunction calibrators like the 725, 726 or 750 Series Calibrators but also extend the measurement range of Fluke pressure calibrators. Since the pressure modules are calibrated independently, they can be swapped from one calibrator to another without a loss of accuracy or traceability.
Measuring pressure with Fluke 750P Series Pressure modules is as easy as connecting the module to a pressure source or hand pump, connecting the pressure module cable to the calibrator and then applying pressure from the pressure source. At the touch of a button the measured pressure is displayed digitally on the calibrator in up to 11 different engineering units quickly giving you the data you need. And, with “no tools required” connectors you don’t even need to reach for a wrench to make connections.
When used with the 750 Series Documenting Process Calibrators pressure readings can even be date/time stamped and stored in documented calibration records for later retrieval. This saves time, eliminates errors, and supports compliance with quality standards and regulations.
A complete family of pressure modules
With over 50 pressure modules covering pressure calibration and measurement workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar) finding a model to meet the needs of your specific application is easier than ever. All modules include NPT, metric (BSP) and M20 adapters.
Choose from:
- Differential modules
- Gage modules
- High pressure modules
- Absolute modules
- Vacuum modules
- Dual range modules
- Reference modules
- Intrinsically safe modules
With more than 50 pressure modules to choose from, some of the more popular modules include:
- Fluke 750P00
- Fluke 750P02
- Fluke 750PD2
- Fluke 750P03
- Fluke 750P05
- Fluke 750P06
- Fluke 750P29
Click the Models tab above for a full list of pressure modules.
Designed to go where you work
Pressure instruments are often installed in harsh, hard to reach locations, so you need test tools that handle rough service. 750P Series Pressure Modules feature a rugged protective boot that guards the module against shock and seals against dirt and dust, if you accidently drop them, there’s no need to worry. The 750P series modules are also specified across a broad temperature range. Though more accurate across a narrower temperature range if used indoors, these modules are designed and specified to deliver traceable pressure measurements in environments from -10 °C to +50 °C.