SP TOOLS Non-Contact Digital Tachometer
- LCD display with backlight
- Laser target
- Range: 100-30000rpm,1.7-500rps
- Accuracy: +/-0.1% reading (100.0 -9,999rpm), +/-0.02% reading (10,000 -30,000rpm)
- Auto power off
- 1.5V x 3 AAA batteries
- Protective cover and carrying case
SKU: SP62032
Categories: Diagnostic Tools, Diagnostic Tools, Diagnostic Tools, Other Diagnostic Tools, Speciality Tools, Tachometers
Related products
-
Diagnostic Tools
SP TOOLS Professional Timing Light
- 4 function digital display readout and easy to read backlit LCD
- Heavy duty inductive pick-up and clamps
- One handed operation
- Detachable leads for easy replacement and use
- Protective hand guard for added safety
- Rotating barrel for better aim at timing mark and LCD viewing angle
- Patented Skip circuitry – Tests up to 10,000 RPM
- Easy access slim-line barrel
- Optical correct lens
- Shock resistant boots
- Tachometer: 249 to 9,990 RPM (+/-1% accuracy)
- Advance degrees (2 and 4 cycle DIS and conventional): 0º to 90º (+/- 5º accuracy)
- Dwell: 0º to 180º /2-12 cylinders (+/-1% accuracy)
- Voltage: 10 to 16 volts DC (+/- 1% accuracy)
(0 reviews) -
Diagnostic Tools
INSTRUMENT CHOICE Scarlet Heat Stress Detector
IC-TWL-1SPlease note; These units do not come with formal calibration certificates, if required please contact us to ensure the correct certificate can be provided.Features:– Dash board: Colorful LCD backlight tells you the risk level based on the TWL value. Work-rest schedule and fluid intake are integrated into the display. A countdown timer shows the time remaining before a recommended rest.
– Cup anemometer captures winds from any direction. You do not have to manually decide the wind direction before measuring the wind speed. Compared to the impeller, wind cup is not restricted to the direction of the wind. It considers all the horizontal components of winds that move the anemometer. A silicone pad covers the top of the bearing to prevent it from dust accumulation.– Data Logger : TWL-1S can record data with configurable sampling rate. PC side software helps download the data for further analysis using other analytical tools, and it also synchronizes the date and time of the device with PC.– Optimised Globe: TWL theory considers Mean Radiant Temperature (MRT), the most important parameter governing human energy balance. MRT can be derived from globe temperature (GT) measured by the black-bulb thermometer. The smaller the surface area of the black bulb, the greater the effect of the air temperature and air velocity is, thus causing inaccuracy of the calculation of MRT. Therefore, it needs a modifying formula to adjust it to the standard globe bulb with a diameter of 15 cm. The 7.5 cm globe bulb is the optimal size for a portable based on our research and experiments.– Sensor Protection : Delicate temperature and humidity sensor are well protected by a replaceable polypropylene (PP) filter in a solid shield, exempted the sensors from dust damage and external strike. A silicone pad protects the mechanism of anemometer from dust.Measurement specifications:– Air Temperature (Range): 0-60 C
– Air Temperature (Accuracy): 0.6 C– Globe Bulb Indoor (Range) 0-80 C– Globe Bulb Indoor (Accuracy): 1.0 C (15…40 C); 1.5 C (others)– Globe Bulb Outdoor (Range): 0-80 C– Globe Bulb Outdoor (Accuracy): 1.5 C (15…40 C); 2.0 C (others)– Relative Humidity (Range): 5-95 %rh– Relative Humidity (Accuracy): 3% (at 25 C; 10…90 %rh) 5% (others)– Wind Speed (Range): 0.5 – 10 m/s– Wind Speed (Accuracy): (2% of reading + 0.2) m/sMeter specifications:– Operating range electronics: -1060 C
– Accuracy at 23 5 C: 1.0 %rh / 0.2 K– Power supply / consumption: 4 AAA 3V battery, power supply 4 mA consumption without lighting– Probe protection: Polypropylene plastic cage– Calibration / adjustment: Scarlet calibration kit– Measurement interval: 2 seconds– Back-light: with Back-light– Alarm indicators: Yes– Battery indicator: Low Batt. Display– Software: Scarlet TWLIT– Risk level indicator: Yes. 3 color LCD backlight: red (risk), yellow (med), green (safe)– Data logger: Yes. Min data rate 10 min, 2,000 data.– Connection Interface: Mini USB (UART)– Enclosure material: ABS(0 reviews) -
Diagnostic Tools
SP TOOLS Multimeter Dual Test Lead Set – Alligator & Standard Probe
SET INCLUDES:
- Alligator Clip Test Lead Set
- Standard Probe Test Lead Set
- Suits all SP Multimeters
ALLIGATOR CLIP TEST LEAD SET TO BANANA PLUG
- Insulated finger guarded alligator clips for easy application
- Silicon rubber insulated cable – 1m
- CAT III 1000V, 10A
STANDARD PROBE TEST LEAD SET TO BANANA PLUG
- Multi-rated probe tips with removable cap (CAT IV 600A) are insulated leaving only 2mm of exposed metal to prevent inadvertent bridging of live conductors and accidental short circuits
- Silicon rubber insulated cable – 1m
- CAT III 1000V, 10A
(0 reviews) -
Diagnostic Tools
KLEIN TOOLS Digital Multimeter Electrical Test Kit
- Digital Multimeter measures up to 600V AC/DC voltage, 10A DC current and 2 ohm resistance
- Meter also test batteries, diodes and continuity
- Voltage Tester NCVT-3P has dual-range capabilities to detect from 12 to 1000V AC or 70 to 1000V AC for a broad variety of low-voltage or standard voltage applications
- Bright torch illuminates work area and may be used independent of the NCVT-3P voltage detection function
- ET45 tests AC voltages from 28V to 240V AC at four useful levels aligned with commonly used residential voltages, and DC voltages from 32V to 330V at four common levels
- Built-in test lead holders on back of ET45 hold the leads in one of two positions: one so that they are spaced correctly to test tamper-resistant US-style outlets; and the other for the convenient storage of the test leads
- RT210 detects the most common wiring problems in standard and GFCI receptacles including open ground, reverse polarity, open hot, open neutral and hot/ground reversed
- Receptacle tester works on GFCI outlets and confirms the operation of the ground fault protective device
(0 reviews)






