SP TOOLS Laser Actuated Tachometer
- Non contact measurement of RPM
- RPM range 2.5–99,999
- Instant and total RPM function
- Memory function
- 50mm–2000mm range with reflective tape
- Accuracy +/- 0.05%
Related products
-
Diagnostic Tools
INSTRUMENT CHOICE WBGT Heat Stress Meter
IC800036Please note: These units do not come with formal calibration certificates, if required please contact us to ensure the correct certificate can be provided.Measure heat stress in the field
Benefits and Features:
15 Second Response Time
Audible Alarm
Adjustable to your WBGT Threshold
Indoor/Outdoor Settings
Tripod ThreadsGovernment organizations such as OSHA have set recommended heat stress limits for various activities. WBGT (Wet Bulb Globe Temperature) provides the most accurate determination of the heat stress index based on the cumulative effect of air temperature, air movement, relative humidity, and radiant heat. WBGT Heat Stress Meter IC800036 is a light-weight meter compact enough to carry anywhere to avoid heat exhaustion in public health, sports, military and industrial activities. Highly accurate readings with a typical response time of only 15 seconds. Provides settings for both indoor and outdoor activity and includes an audible alarm, adjustable to your WBGT threshold. Can be mounted on standard camera tripod (not supplied).
Globe diameter: 40 mm
Meter dim: 255 50 30 mm
Weight: 126 g(0 reviews) -
Diagnostic Tools
INSTRUMENT CHOICE Multi-Function 4 in 1 Thermometer
The LM-8000A is a four-in-one anemometer, humidity reader, light meter and thermometer. Its rugged and lightweight design was created to make it easy to use in the field. Each of the measurements is highly accurate, and the unit stores maximum and minimum data for each of its functions. The LM-8000As data hold feature makes it easy to use even. The unit has a built-in microprocessor circuit to ensure excellent accuracy and performance.
Each of the units four functions is performed via the usage of the latest high-tech equipment.
What does the LM-8000A measure?
Temperature
Humidity
Wind Speed/Air Velocity
LightFeatures
Four-in-one Anemometer, Hygrometer, Thermometer and Light Meter.
Suitable for one-handed operation
Hold button freezes the current reading
Internal temperature and humidity sensor
Stores the minimum and maximum readings for all four settings
Highly accurate low-friction ball vane wheels design
Utilises a standard type K thermocouple outlet
Performance and accuracy are supplied by the built-in microprocessor circuitSpecifications
Measures temperatures from 0 to 50C (Internal Thermistor)
Measures temperatures from -100 to 1300C (Thermocouple input)
Measures light from 0 to 20,000 Lux
Measures relative humidity from 10 to 95 percent
Measures air velocity from 80 to 5910 ft/min, 0.4 to 30.0 m/s, 1.4 to 108.0 km/h, 0.9 to 67.0 mile/h and 0.8 to 58.3 knotsPower Requirements
006P DC 9V batteryMeasurements
156 mm x 60 mm x 33 mmWarranty
24 Months
(0 reviews) -
Diagnostic Tools
INSTRUMENT CHOICE Data Logging Particulate Monitor sensor with the Series 500 Handheld
IC-PM-500
This kit comes supplied with the IC-PM and the IC-HH S500L handheld monitor. The IC-PM is Aeroqual’s portable particulate monitor for accurate and simultaneous measurement of PM10 and PM2.5 in ambient outdoor and indoor environments. Whilst the Series 200 will allow you to view these results in real time and if desired purchase additional sensor heads to monitor other gases.
Series 500 Lithium Air Quality Portable Monitor features and specifications:Features:– Simple to use, easy to maintain, multiple applications.– Interchangeable gas sensor heads.– Field replaceable long life Lithium battery (up to 8 hours).– Minimum, maximum and average readings.Specifications:– Measurement units: Gas: ppm or mg/m3 | Humidity: % | Temperature C or F– Reading functions: Instant, minimum, maximum, average– Sensor head: Interchangeable, replaceable– Display status indicators: Battery, sensor, standby– Sensor calibration: Zero and gain calibration– Analog output: 0-5 V– Digital Interface: RS-232 to USB– Data logging: Up to 8,188 records (2706 incl. Temp/RH)– PC data logging (Windows 7, 8, XP): Software and data cable supplied. Link data to a specific location and monitor.– Clock function: Real time– Power supply: 12V DC (power adaptor/charger supplied 100-250 V AC)– Rechargeable battery: Lithium polymer 12 V DC 2700 mA/h– Enclosure material and rating: PC and ABS; IP20 and NEMA 1 equivalent– Size (with sensor head): (L x W x D) 195 x 122 x 54 (mm); 7 x 4 x 2 (in)– Environmental operating conditions: Temperature: -5 C to 45 C/Humidity: 0 to 95 % non-condensing– Temperature & Humidity sensor: Range – 40 C to 124 C (- 40 F to 255 F); Range 0 to 100 % RHParticulate Matter Sensor features and specifications:The IC-PM is Aeroqual’s portable portable particulate monitor for accurate and simultaneous measurement of PM10 and PM2.5 in ambient outdoor and indoor environments. Compatible with Aeroqual’s Series 200/300/500 air quality monitors, the portable particulate monitor will output particulate matter (PM) measurements for PM10 and PM2.5 in real-time.– Range: 0.000 to 1.000 mg /m3– Measurement Parameters: PM2.5 and PM10– Sensor Type: Laser particle counter– Minimum Detection Limit: 0.001 mg/m3– Accuracy of Factory Calibration: +/- (0.002 mg/m3 + 15 % of reading)– Resolution: 0.001 mg/3– Response Time: 5 Seconds– Temp: 0 to 40C– Relative Humidity: 0 to 90% non-condensating(0 reviews) -
Diagnostic Tools
INSTRUMENT CHOICE WBGT Meter with Color-Coded LCD
IC-801038This unique heat stress meter features bright multi-color LCD backlights corresponding to OSHA’s heat stress alert levels. This visual alert system can be seen at a distance allowing management and workers to be instantly aware when the heat index enters potentially dangerous zones.The 801038 also calculates heat stress values for direct sunlight and shade and displays humidity, maximum and minimum ambient (TA) and black globe (TG) temperatures. Also indicates low battery and a hold function. Comes complete with clear instructions, integrated tripod screw and 4 AAA batteries.SpecificationsAmbient Air temperature:– Range: 0 to 50 C (32 to 122 F)
– Resolution: 0.1– Accuracy: +/- 0.6 C (1.5 F)Globe Temperature:– Range: 0 to 80 C (32 to 176 F)
– Resolution: 0.1– Accuracy: +/- 1 C at 15 to 40 C; +/- 2 C outside this rangeRelative Humidity:– Range: 5 to 90%
– Resolution: 0.1– Accuracy: +/- 4%WBGT:– Range: 0 to 50 C (32 to 122 F)
– Resolution: 0.1– Accuracy: +/- 1 C at 15 to 40 C; +/- 2 C outside this range(0 reviews)