INSTRUMENT CHOICE Scarlet Heat Stress Detector

IC-TWL-1S
Please note; These units do not come with formal calibration certificates, if required please contact us to ensure the correct certificate can be provided.
Features:

– Dash board: Colorful LCD backlight tells you the risk level based on the TWL value. Work-rest schedule and fluid intake are integrated into the display. A countdown timer shows the time remaining before a recommended rest.

– Cup anemometer captures winds from any direction. You do not have to manually decide the wind direction before measuring the wind speed. Compared to the impeller, wind cup is not restricted to the direction of the wind. It considers all the horizontal components of winds that move the anemometer. A silicone pad covers the top of the bearing to prevent it from dust accumulation.
– Data Logger : TWL-1S can record data with configurable sampling rate. PC side software helps download the data for further analysis using other analytical tools, and it also synchronizes the date and time of the device with PC.
– Optimised Globe: TWL theory considers Mean Radiant Temperature (MRT), the most important parameter governing human energy balance. MRT can be derived from globe temperature (GT) measured by the black-bulb thermometer. The smaller the surface area of the black bulb, the greater the effect of the air temperature and air velocity is, thus causing inaccuracy of the calculation of MRT. Therefore, it needs a modifying formula to adjust it to the standard globe bulb with a diameter of 15 cm. The 7.5 cm globe bulb is the optimal size for a portable based on our research and experiments.
– Sensor Protection : Delicate temperature and humidity sensor are well protected by a replaceable polypropylene (PP) filter in a solid shield, exempted the sensors from dust damage and external strike. A silicone pad protects the mechanism of anemometer from dust.
Measurement specifications:

– Air Temperature (Range): 0-60 C

– Air Temperature (Accuracy): 0.6 C
– Globe Bulb Indoor (Range) 0-80 C
– Globe Bulb Indoor (Accuracy): 1.0 C (15…40 C); 1.5 C (others)
– Globe Bulb Outdoor (Range): 0-80 C
– Globe Bulb Outdoor (Accuracy): 1.5 C (15…40 C); 2.0 C (others)
– Relative Humidity (Range): 5-95 %rh
– Relative Humidity (Accuracy): 3% (at 25 C; 10…90 %rh) 5% (others)
– Wind Speed (Range): 0.5 – 10 m/s
– Wind Speed (Accuracy): (2% of reading + 0.2) m/s
Meter specifications:

– Operating range electronics: -1060 C

– Accuracy at 23 5 C: 1.0 %rh / 0.2 K
– Power supply / consumption: 4 AAA 3V battery, power supply 4 mA consumption without lighting
– Probe protection: Polypropylene plastic cage
– Calibration / adjustment: Scarlet calibration kit
– Measurement interval: 2 seconds
– Back-light: with Back-light
– Alarm indicators: Yes
– Battery indicator: Low Batt. Display
– Software: Scarlet TWLIT
– Risk level indicator: Yes. 3 color LCD backlight: red (risk), yellow (med), green (safe)
– Data logger: Yes. Min data rate 10 min, 2,000 data.
– Connection Interface: Mini USB (UART)
– Enclosure material: ABS

In Stock