FLUKE Calibration 9173 Metrology Well
- Exceptional stability (±0.005 °C) and axial uniformity (±0.02 °C over a 60 mm zone).
- Immersion depth to 203 mm (8 in)
- Optional ITS-90 reference input reads PRTs to ±0.006 °C
- Wide Temperature range from –45 °C to 700 °C
Related products
-
Temperature Calibrators
FLUKE 9132/9133 Portable Infrared Calibrator with Blackbody Source
Product overview: Fluke 9132/9133 Portable Infrared Calibrator with Blackbody Source
Reliable, Portable Blackbody Calibration for IR Thermometers and Imagers
Fluke’s 9132 and 9133 infrared calibrators are designed to meet the precise needs of infrared thermometer and thermal imager users. These portable blackbody sources offer fast heating and cooling, stable temperatures, and radiometric accuracy—making them ideal for field and lab environments alike.
Fluke 9132 – High-Temperature Blackbody Source (Up to 500 °C)
- Designed for IR calibrations above ambient
- Provides a stable blackbody surface up to 500 °C (932 °F)
- Short heating and cooling times keep workflows efficient
- Radiometric calibration ensures measurement confidence across its entire range
Fluke 9133 – Low-Temperature Blackbody Source (–30 °C to 150 °C)
- Ideal for calibrating IR thermometers at low temperatures
- Reaches –30 °C (22 °F) in typical ambient conditions using solid-state cooling
- Convenient dry gas fitting on front bezel prevents ice buildup on the target
- Offers stable temperature control up to 160 °C (320 °F)
- Heats or cools from ambient to either extreme in approximately 15 minutes
What is a Blackbody Calibrator?
A blackbody calibrator (or blackbody source) is a device that emits thermal radiation with high emissivity, typically near 1.0. This makes it behave closely to an ideal blackbody, emitting radiation according to Planck’s law.
Blackbody calibrators are essential tools for ensuring the accuracy of:
- Infrared thermometers
- Thermal imagers
- Non-contact temperature measurement devices
By aiming a device under test at the precisely controlled blackbody target, users can verify and adjust readings to ensure accuracy and compliance with calibration standards.
Summary: Why Choose the 9132 or 9133?
Model Temperature Range Ideal For 9132 Up to 500 °C (932 °F) High-temperature IR calibration 9133 –30 °C to 160 °C (–22 °F to 320 °F) Low-temperature IR calibration with fast transitions Both units provide:
- Portable, stable blackbody sources
- Quick heating and cooling times
- High emissivity targets for accurate infrared calibration
- Confidence backed by Fluke’s precision and reliability
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 9009 Dual-Well Dry-Well
Two blocks. One portable calibrator. Full temperature coverage.
Dual Independent Temperature Blocks
The Fluke Calibration 9009 combines two independently controlled temperature blocks into one compact, rugged system:
- Hot block range: 50 °C to 350 °C
- Cold block range: –15 °C to 110 °C
- Each block is powered by a precision Hart Scientific temperature controller—not off-the-shelf components, but industry-leading technology from the world’s top temperature calibration experts.
Flexible Multi-Probe Calibration
Each block includes two wells with removable inserts, giving you unmatched flexibility:
- Calibrate up to four probes simultaneously
- Use two probes with an external reference thermometer (e.g., Hart 1521 LLK)
- Perform quick zero/span checks for transmitter calibration with both blocks in use
Portable and Field-Ready
The 9009 is built for portability and field durability:
- Housed in a rugged Pelican™ case—airtight, watertight, and impact-resistant
- Weighs only 10 lbs (4.5 kg), compact and easy to carry
- Internal storage holds the power cord and four extra inserts
- Inserts available for sensor sizes from 1/16” (1.6 mm) to 7/16” (11.1 mm)
This system is truly ready to go wherever your work takes you.
Reliable Accuracy and Stability
Performance you expect from a Fluke/Hart Scientific source:
Block Display Accuracy Stability Cold ±0.2 °C ±0.05 °C Hot ±0.6 °C ±0.05 °C NIST-traceable calibration certificate included for both blocks.
PC Connectivity and Automation
- RS-232 interface included for temperature monitoring and control via PC
- Fully compatible with MET/TEMP II software for automated calibration of RTDs, thermocouples, and thermistors
The Complete Field Calibration Package
With the Fluke 9009 Dual-Well Dry-Well, you get:
- Two independent blocks
- Full temperature coverage from –15 °C to 350 °C
- True field portability in a compact, durable case
- Flexibility for multiple sensors and calibration modes
- Built-in automation and PC integration
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 9103/9140 Field Dry-Well
Portable, fast, and accurate temperature sources for on-site calibration
Exceptional Performance in a Compact Design
The Fluke 9103 and 9140 Field Dry-Wells outperform the competition in nearly every category—performance, size, weight, ease of use, calibration simplicity, software integration, and price.
Each unit features:
- Adjustable heating and cooling rates via the front panel
- Thermal switch actuation testing
- Multiple-hole inserts for compatibility with a wide range of probe sizes
Fast Calibration with Minimal Downtime
- Units are easy to calibrate without opening the case, reducing maintenance costs and downtime
- All units include a NIST-traceable calibration certificate at no additional charge
- Factory-tested for accuracy and reliability before shipment
Software Integration
Fluke’s Interface-it software supports:
- Set-point and ramp rate control
- Real-time temperature logging
- Electronic strip chart creation
- Thermal switch test automation with data collection
- Windows-based interface with intuitive graphical controls
Whether you need basic control or full automation, Fluke has a software solution ready.
Fluke 9103 – Low-Temperature Field Dry-Well
- Temperature Range: Down to –25 °C (actual, not below ambient)
- Stability: ±0.02 °C
- Display Accuracy: ±0.25 °C across full range
- Speed:
- Reaches 0 °C in 8 minutes
- Reaches 100 °C in 6 minutes
Key Advantage:
Many competitors advertise –45 °C below ambient, which only reaches around –20 °C. The 9103 delivers a true –25 °C in standard room conditions—no walk-in freezer required.
Insert Options:
Choose from four removable inserts to suit your calibration needs:
- Insert A: One well each from 1/16” to 1/2”
- Insert B: Two wells each of 3/8”, 1/4”, and 3/16” (ideal for comparison calibrations)
- Insert C: Six 1/4” wells for multiple probe calibrations
- Insert D: Three pairs of metric-sized wells
Fluke 9140 – Mid-Temperature Field Dry-Well
- Temperature Range: 35 °C to 350 °C
- Stability: ±0.05 °C or better
- Uniformity:
- 0.1 °C in small-diameter wells
- 0.4 °C in largest-diameter wells
- Speed: Reaches max temperature in 12 minutes
- Size: Weighs only 6 lbs, easily portable with one hand
- Display Accuracy: ±0.5 °C
For improved calibration accuracy, use an external thermometer alongside the built-in display.
Insert Options:
Three removable inserts available to accommodate various probe sizes.
Why Choose the 9103 or 9140?
Model Temperature Range Stability Display Accuracy Key Benefits 9103 –25 °C to 110+ °C ±0.02 °C ±0.25 °C True sub-ambient performance without freezer 9140 35 °C to 350 °C ±0.05 °C ±0.5 °C Light, fast, and ideal for field portability Both models are:
- Reliable for industrial and lab environments
- Versatile with multiple insert options
- Backed by Fluke’s proven calibration technology
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 1502A/1504 Thermometer Readout
Precision thermometer readouts for laboratory and field use
1502A Tweener PRT Readout
The Fluke Calibration 1502A Tweener offers precision temperature measurement with:
- Accuracy up to ±0.006 °C
- Resolution of 0.001 °C across the entire range
- Compatibility with 100-ohm, 25-ohm, and 10-ohm RTD probes
- Smallest unit in its class, ideal for field or bench use
- Optional 9320A Battery Pack for full portability
Advanced Features
- Programmable to match a probe’s constants for maximum linearity and accuracy
- Displays temperature in °C, °F, K, or resistance in ohms
- Reads standard industrial IEC-751 / “385 ALPHA” RTDs with no programming required
- Accepts ITS-90 subranges 4 and 6–11, with formulas built into firmware
- Calibration is done digitally via front-panel—no need to open the device
- Comes with RS-232 interface; optional IEEE-488 interface available
1504 Tweener Thermistor Readout
Need higher precision in a narrower temperature range? The Model 1504 Tweener offers:
- Accuracy up to ±0.002 °C
- Resolution of 0.0001 °C
- Designed specifically for thermistors—more robust, shock-resistant sensors with faster response times
- Ideal for applications requiring high sensitivity and reliability in limited temperature spans
Calibration and Probe Integration
- Each Tweener and its compatible probe (sold separately) include individual calibration reports
- System data is available upon request at two or more temperatures for high-precision needs (Calibration Model 1929-X)
- Users can calculate system accuracy using individual device specifications—no need to purchase system-level data unless required
Software Compatibility
Enhance your workflow with Fluke software tools:
- 9934 LogWare: Real-time data acquisition, graphing, and analysis
- MET/TEMP II: Use Tweeners as reference thermometers for automated calibrations
Optional Battery Pack
Take your Tweener on the road with the 9320A Battery Pack:
- Provides up to 36 hours of portable operation between charges
- Perfect for fieldwork or locations without direct power access
(0 reviews)