FLUKE Calibration 9102S Handheld Dry-Well
- Temperature ranges from –10°C to 375°C.
- Accuracy to ±0.25°C, with stability of ±0.05°C at 0°C.
- Equipped with an RS-232 interface for connectivity.
Related products
-
Temperature Calibrators
FLUKE Calibration 1524 Handheld Thermometer Readout
Make accurate, consistent measurements… anywhere.
You need accuracy for compliance, product yields, energy savings, and consistent results. The 1524 uses current reversal, a technique used in high-end instruments that eliminates thermal EMFs, for precision temperature measurements. Specifications are guaranteed from -10 °C to 60 °C ambient. Special precision resistors and a highly stable reference voltage source keep 1524 accuracy virtually insensitive to environmental temperature.
Like all Fluke handheld tools, the 1524 Reference Thermometers endure rigorous testing in temperature extremes and under harsh conditions of vibration, so you can take them anywhere you need to go.
An optional magnetic hanger allows you to hang the thermometer for easy viewing while freeing your hands to focus on the job.
INFO-CON connectors ensure correct temperature conversion
Inside the INFO-CON, a memory chip keeps calibration information for the attached probe. Simply plugging in the probe uploads the information to the readout, ensuring the correct temperature conversion for accurate, hassle-free measurements.
Probes may be locked by password to specific channels and readouts for security or for system calibration traceability. Plug any thermocouple with mini-thermocouple jacks into an optional universal thermocouple adapter for convenient measurement. Each thermocouple adapter or standard connector supports reference junction compensation (RJC) with its own internal precision thermistor.
Monitor trends in the lab or in the field
See trends graphically on the 1524 thermometer’s 128×64-backlit LCD display. You can change the graph’s resolution at the touch of a button. Now it’s easy to see when the temperature is stable, without statistics or long delays, or monitor processes over time to verify correct operation.
Document on demand up to 25 readings and associated statistics for easy retrieval. You can view the data through the display or by uploading it to a PC via RS-232 connection and 9940 software, included free. To monitor and log more data over time, use a PC and optional LogWare II software.
RS-232-to-USB adapters are available for those who prefer USB connectors. Battery power lasts at least 20 hours on three AA batteries, or use the dc power adapter for extended periods of measurement. Power saving features can be enabled or disabled for longer battery life or greater convenience.
Applications
The new 1524 Reference Thermometers help you do twice the work in half the time. Two channels and three sensor types and high-speed measurement make you more productive and make model 1524 the one reference thermometer you need to own. It has all the features of the 1523, and it’s a data logger too. A real-time clock and memory for 15,000 time and date stamped measurements mean everything you are going to need is in this package. Log up to three times per second, or once every hour or other options in between. Download the data to a PC for analysis when you need it.
Calibration, loop checking, plant startup, troubleshooting, maintenance, and repair are some of the varied duties that need a 1524 thermometer. Use it for a handy temperature reference in baths, dry-block calibrators, thermowells, clean rooms, engines, heat exchangers, furnaces, freezers, or anything else that must be calibrated, checked, or maintained.
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 1502A/1504 Thermometer Readout
Precision thermometer readouts for laboratory and field use
1502A Tweener PRT Readout
The Fluke Calibration 1502A Tweener offers precision temperature measurement with:
- Accuracy up to ±0.006 °C
- Resolution of 0.001 °C across the entire range
- Compatibility with 100-ohm, 25-ohm, and 10-ohm RTD probes
- Smallest unit in its class, ideal for field or bench use
- Optional 9320A Battery Pack for full portability
Advanced Features
- Programmable to match a probe’s constants for maximum linearity and accuracy
- Displays temperature in °C, °F, K, or resistance in ohms
- Reads standard industrial IEC-751 / “385 ALPHA” RTDs with no programming required
- Accepts ITS-90 subranges 4 and 6–11, with formulas built into firmware
- Calibration is done digitally via front-panel—no need to open the device
- Comes with RS-232 interface; optional IEEE-488 interface available
1504 Tweener Thermistor Readout
Need higher precision in a narrower temperature range? The Model 1504 Tweener offers:
- Accuracy up to ±0.002 °C
- Resolution of 0.0001 °C
- Designed specifically for thermistors—more robust, shock-resistant sensors with faster response times
- Ideal for applications requiring high sensitivity and reliability in limited temperature spans
Calibration and Probe Integration
- Each Tweener and its compatible probe (sold separately) include individual calibration reports
- System data is available upon request at two or more temperatures for high-precision needs (Calibration Model 1929-X)
- Users can calculate system accuracy using individual device specifications—no need to purchase system-level data unless required
Software Compatibility
Enhance your workflow with Fluke software tools:
- 9934 LogWare: Real-time data acquisition, graphing, and analysis
- MET/TEMP II: Use Tweeners as reference thermometers for automated calibrations
Optional Battery Pack
Take your Tweener on the road with the 9320A Battery Pack:
- Provides up to 36 hours of portable operation between charges
- Perfect for fieldwork or locations without direct power access
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 9143 Field Metrology Well
Built-in features to address large workloads and common applications
Whether you need to calibrate 4-20 mA transmitters or a simple thermostatic switch, a Field Metrology Well is the right tool for the job. With three models covering the range of –25 °C to 660 °C, this family of Metrology Wells calibrates a wide range of sensor types. The optional process version (models 914X-X-P) provides a built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24 V loop supply to power the transmitter.
Each process version accepts an ITS-90 reference PRT. The built-in readout accuracy ranges from ±0.01 °C to ±0.07 °C depending on the measured temperature. Reference PRTs for Field Metrology Wells contain individual calibration constants that reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably. The second channel is user-selectable for 2-, 3-, or 4-wire RTDs, thermocouples, or 4-20 mA transmitters. For comparison calibration, don’t hassle with carrying multiple instruments to the field. Field Metrology Wells do it all as a single instrument.
Traditionally, calibrations of temperature transmitters have been performed on the measurement electronics, while the sensor remained uncalibrated. Studies have shown, however, that typically 75% of the error in the transmitter system (transmitter electronics and temperature sensor) is in the sensing element. Thus, it becomes important to calibrate the whole loop—both electronics and sensor.
The process option of Field Metrology Wells makes transmitter loop calibrations easy. The transmitter sensor is placed in the well with the reference PRT and the transmitter electronics are connected to the front panel of the instrument. With 24 V loop power, you are able to power and measure the transmitter current while sourcing and measuring temperature in the Field Metrology Well. This allows for the measurement of as-found and as-left data in one self-contained calibration tool.
All Field Metrology Wells allow for two types of automated thermostatic switch test procedures—auto or manual setup. Auto setup requires the entry of only the nominal switch temperature. With this entry, it will run a 3-cycle calibration procedure and provide final results for the dead band temperature via the display. If you need to customize the ramp rate or run additional cycles, the manual setup allows you to program and run the procedure exactly how you would like. Both methods are fast and easy and make testing temperature switches a virtual joy!
Metrology performance for high-accuracy measurements
Unlike traditional dry-wells, Field Metrology Wells maximize speed and portability without compromising the six key metrology performance criteria laid out by the EA: accuracy, stability, axial (vertical) uniformity, radial (well-to-well) uniformity, loading, and hysteresis. All criteria are important in ensuring accurate measurements in all calibration applications. Field Metrology Well displays are calibrated with highquality traceable and accredited PRTs. Each device (process and non-process versions) comes with an IEC-17025 NVLAP-accredited calibration certificate, which is backed by a robust uncertainty analysis that considers temperature gradients, loading effects, and hysteresis. The 9142 and 9143 have a display accuracy of ±0.2 °C over their full range, and the 9144 display accuracy ranges from ±0.35 °C at 420 °C to ±0.5 °C at ±660 °C. Each calibration is backed with a 4:1 test uncertainty ratio.
New control technology guarantees excellent performance in extreme environmental conditions. The 9142 is stable to ±0.01 °C over its full range and the mid-range 9143 is stable from ±0.02 °C at 33 °C and ±0.03 °C at 350 °C. Even at 660 °C, the 9144 is stable to ±0.05 °C. But this is not all! Thermal block characteristics provide radial (well-towell) uniformity performance to ±0.01 °C. Dual-zone control helps these tools achieve axial uniformity to ±0.05 °C at 40 mm (1.6 in).
Automation and documentation make each unit a turnkey solution
So you now have a precision calibration instrument that has field-ready characteristics, accredited metrology performance, built-in two-channel thermometry, and automation— what else could you ask for? How about all this and a turnkey solution that will automate and document the results?
The process versions of Field Metrology Wells have onboard non-volatile memory for documentation of up to 20 tests. Each test can be given a unique alphanumeric ID and will record block temperature, reference temperature, UUT values, error, date, and time. Each test can be easily viewed via the front panel. Use the 1586A Super-DAQ to automate temperature sensor calibration with these Field Metrology Wells.
Operation is as easy as 1-2-3
You’ll find Field Metrology Wells intuitive and easy to use. Each unit is equipped with a large, easy-to-read LCD display, function keys, and menu navigation buttons. Its “SET PT.” button makes it straightforward and simple to set the block temperature. Each product has a stability indicator that visually and audibly tells you the Field Metrology Wells is stable to the selectable criteria. Each unit offers preprogrammed calibration routines stored in memory for easy recall, and all inputs are easily accessible via the front panel of the instrument. Never buy a temperature calibration tool from a company that only dabbles in metrology (or doesn’t even know the word). Metrology Wells from Fluke are designed and manufactured by the same people who equip the calibration laboratories of the world’s leading temperature scientists. These are the people around the world who decide what a Kelvin is! We know a thing or two more about temperature calibration than the vast majority of the world’s dry-well suppliers. Yes, they can connect a piece of metal to a heater and a control sensor. But we invite you to compare all our specs against the few that they publish. (And by the way, we meet our specs!).
Small dry wells for big field applications
The 9142, 9143, 9144 Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.
Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the “process” option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4–20 mA current with 24 volt loop power. It also has on-board automation and documentation. Combined, the three models (9142, 9143, and 9144—each with a “process” option) cover the wide range of –25 °C to 660 °C.
High performance for the industrial environment
Field Metrology Wells are designed for the industrial process environment and fast speed to temperature. They weigh less than 8.2 kg (18 lb) and have a small footprint, which makes them easy to transport.
Field environment conditions are typically unstable, having wide temperature variations. Each Field Metrology Well has a built-in gradient-temperature compensation (patent pending) that adjusts control characteristics to ensure stable performance in unstable environments. In fact, all specifications are guaranteed over the environmental range of 13 °C to 33 °C.
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 9009 Dual-Well Dry-Well
Two blocks. One portable calibrator. Full temperature coverage.
Dual Independent Temperature Blocks
The Fluke Calibration 9009 combines two independently controlled temperature blocks into one compact, rugged system:
- Hot block range: 50 °C to 350 °C
- Cold block range: –15 °C to 110 °C
- Each block is powered by a precision Hart Scientific temperature controller—not off-the-shelf components, but industry-leading technology from the world’s top temperature calibration experts.
Flexible Multi-Probe Calibration
Each block includes two wells with removable inserts, giving you unmatched flexibility:
- Calibrate up to four probes simultaneously
- Use two probes with an external reference thermometer (e.g., Hart 1521 LLK)
- Perform quick zero/span checks for transmitter calibration with both blocks in use
Portable and Field-Ready
The 9009 is built for portability and field durability:
- Housed in a rugged Pelican™ case—airtight, watertight, and impact-resistant
- Weighs only 10 lbs (4.5 kg), compact and easy to carry
- Internal storage holds the power cord and four extra inserts
- Inserts available for sensor sizes from 1/16” (1.6 mm) to 7/16” (11.1 mm)
This system is truly ready to go wherever your work takes you.
Reliable Accuracy and Stability
Performance you expect from a Fluke/Hart Scientific source:
Block Display Accuracy Stability Cold ±0.2 °C ±0.05 °C Hot ±0.6 °C ±0.05 °C NIST-traceable calibration certificate included for both blocks.
PC Connectivity and Automation
- RS-232 interface included for temperature monitoring and control via PC
- Fully compatible with MET/TEMP II software for automated calibration of RTDs, thermocouples, and thermistors
The Complete Field Calibration Package
With the Fluke 9009 Dual-Well Dry-Well, you get:
- Two independent blocks
- Full temperature coverage from –15 °C to 350 °C
- True field portability in a compact, durable case
- Flexibility for multiple sensors and calibration modes
- Built-in automation and PC integration
(0 reviews)