FLUKE 9190A Ultra-Cool Field Metrology Well
Ideal for cleanroom environments and demanding calibration work
Cleanroom-Compatible, Ultra-Portable, and Fast
Traditional calibration baths are known for stability and uniformity—but they’re far from ideal for cleanroom use. Their large size, fluid handling requirements, and potential for spills or vapors make them a poor fit for controlled environments.
The Fluke 9190A Ultra-Cool Field Metrology Well offers a smarter solution. Designed specifically for cleanrooms and critical process industries, it provides:
- Wide temperature range suitable for pharmaceutical, biomedical, and food processing needs
- Compact, lightweight design for easy transport and field use
- No heat transfer fluids, keeping your environment contaminant-free
- Faster heating and cooling times than traditional calibration baths—so you complete calibrations faster
Precision You Can Trust for Process Accuracy
Accurate process measurements are essential for quality control. Inaccurate data can lead to product recalls, regulatory penalties, lost profits, and reputational damage. That’s why your calibration equipment needs to be just as dependable as your measurement systems.
The 9190A Ultra-Cool Field Metrology Well delivers:
- Best-in-class accuracy, stability, and uniformity
- Designed using decades of Fluke dry-block technology expertise
- Conformance to EURAMET cg-13 best practices for temperature block calibrators
- Thoroughly tested specs for axial and radial uniformity, hysteresis, and loading effects
Make Every Measurement Count
When you use the 9190A, you’re choosing the most accurate and stable ultra-cool dry-block calibrator available. That confidence translates into better product quality, more efficient compliance, and measurable business impact.
Related products
-
Intrinsically Safe
FLUKE 1551A/1552A Intrinsically Safe Thermometers
Product overview: Fluke 1551A/1552A Intrinsically Safe Thermometers
The Fluke 1551A “Stik” Thermometer provides a temperature range—50 °C to 160 °C (-58 °F to 320 °F). The Fluke 1551A delivers repeatable temperature measurements accurate to ±0.05°C over its full range. It is rated intrinsically safe for working in indoor or outdoor environments where potentially explosive gases may be present. It’s a great choice for environments that aren’t potential explosive as well such as the floor of a processing plant. The battery operated, portable reference thermometer is a great choice for daily checks of working thermometers, custody transfer temperature determination, PET calibration, LIG calibration, and temperature transmitter calibration and verification.
The stainless steel probe and digital readout are fixed together and calibrated as a system. The large backlit LCD display rotates 90° degrees making it easy to read from any angle. And a user-configurable stability/trend indicator lets you know when your temperature is stable enough to record an accurate measurement. A user-settable auto-off function extends typical battery life to up to 300 hours. And the low-battery indicator and stop-measure function prevents erroneous measurements from being made due to a low battery. Plus you can easily and accurately calibrate the 1551A with a simple three-point calibration function.
Other useful features:
- Delivers 300-hour battery life
- Shows percent battery-life and low-battery indicators
- Includes NVLAP-accreditation and NIST-traceable calibration
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 6109A / 7109A Portable Calibration Baths
Four times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators
Process manufacturing plants for pharmaceuticals, biotechnology, and food production utilize many sanitary temperature sensors that require regular calibration. Production must stop while the calibrations are taking place. Therefore, more calibration throughput means less plant downtime. And in businesses where even a few tenths of a degree Celsius can cost thousands of dollars in ruined product, temperature accuracy is crucial to maintaining quality.
The Fluke Calibration 6109A and 7109A Portable Calibration Baths let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other baths in this class. Up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges.
Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe.
Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.
Facilities managers who need to meet U.S. FDA and ISO clean room standards like the baths’ stainless steel casing that stands up to harsh cleaning solutions. They depend on the 6109A and 7109A to help maintain the accuracy of the plant’s temperature sensors, thus reducing the possibility of an expensive product batch loss.
Production engineers also appreciate the baths’ accuracy, which helps them control sensor out-of-tolerance conditions. Moreover, they prefer to use a bath designed specifically for clean room calibration throughput. No more need to make do with equipment designed for some other application.
Calibration technicians who perform calibrations on platforms, in crawl spaces, and other hard-to-reach parts of the plant enjoy the portability and clean room compatibility (i.e. easy to sanitize, don’t harbor bacteria) of these baths.
Global Fluke Calibration service and support ensure that your 6109A and 7109A baths will give you years of service that you can trust.
Calibrate more sanitary sensors at a time – with confidence
The 6109A and 7109A baths calibrate most temperature sensor applications used in clean process manufacturing, including pharmaceutical bioreactors (-10 C to 100 °C), chemical reactors (200 °C), steam-in-place process (122 °C to 140 °C), autoclave sterilization (120 °C to 135 °C), food storage freezers (-25 °C), and food processing (0 °C to 220 °C).
A large tank volume (112 mm square tank opening x 154 mm depth) lets you immerse up to four sanitary sensors at the same time. Calibrate a batch of odd shaped sensors of varying lengths and diameters, and still have room for a reference thermometer. Fast heating and cooling times let you get the job done without spending a lot of time waiting for the bath to come to temperature and stabilize. Increase your sanitary sensor calibration throughput and decrease expensive production downtime.
Excellent system display accuracy of ± 0.1 °C. Accuracy covers all sources of error including calibration uncertainty, stability, uniformity, and repeatability. NVLAP accredited calibration is included standard. Fluke Calibration’s high metrological standards and conservative specifications mean you can have confidence in the measurements you make with the 6109A and 7109A Portable Calibration Baths.
Take these portable baths almost anywhere, including the clean room
The 6109A weighs 16 kilograms (35 pounds) and the 7109A weighs 20 kilograms (44 pounds). They each feature a fixed, non-rotating bail handle, enabling most people to carry a bath with one hand. Single-handed carrying comes in handy when the job includes walking up and down stairs, across catwalks, and into other hard-to-reach environments. Two recessed handles on the bottom of each bath also make it easy to move from a shelf to a cart or benchtop. A sealed lid protects against fluid spills while moving the bath.
Stainless steel casing stands up to the harsh chemicals used to sterilize equipment for clean room use. Synthetic materials used for decals, keypads and feet do not harbor bacteria. The keypad is sealed against moisture ingress to protect against damage during cleaning or in non-controlled environments.
Easy to use and maintain
Each bath features a large color display that indicates date and time, bath fluid temperature, setpoint temperature, control indicator when the fluid is at setpoint, and heating status. A ready indicator changes color from amber to green, giving you 360-degree visual indication when the bath fluid has reached its setpoint temperature and is ready for you to start making measurements.
A hot warning indicator lights up if the fluid temperature reaches above 60 °C, warning the operator that the bath fluid and tank area are hot and should not be touched.
An adjustable probe fixture holds up to four tri-clamp sensors securely inside the tank opening during calibration. An optional single probe clamp kit holds a reference probe.
Fluid spills create mess and potential safety hazards. The 6109A and 7109A include an overflow tube that directs excess bath fluid into an optional overflow container. A drain tube makes it easy to remove bath fluid for replacement or transport.
I own a Fluke Calibration Micro-Bath. Why do I need a 6109A or 7109A bath?
If you already own a Fluke Calibration Micro-Bath or dry-block calibrator, thank you for being a customer! We hope you are enjoying the portability and stability of these popular products.
However, there are a few reasons why you should consider adding a 6109A or 7109A bath:
Errors of just a few tenths of a degree Celsius can cause expensive losses in ruined product. The 6109A and 7109A baths are twice as accurate as a Micro-Bath, helping you to reduce this risk. The 6109A and 7109A have four times the calibration throughput of a Micro-Bath, which can only calibrate a single tri-clamp sensor at a time. They’re made with materials that don’t harbor bacteria. Their stainless steel panels and tank are easy to clean and rust resistant–perfect for clean room use. We hope you will continue to use your Fluke Calibration Micro-Bath for many years to come. The 6109A or 7109A baths will also serve you well if you need the throughput, accuracy, and clean room readiness that they provide.
Backed by global Fluke support and service
The 6109A and 7109A are designed to meet demanding Fluke Calibration metrology specifications, so you can trust that they will perform the way we say they will. Need assistance? We offer world-class support both before and after the sale, via online chat, email, telephone and through our service organizations. Rest easy knowing the value of your investment will be preserved now and into the future.
(0 reviews) -
Temperature Calibrators
FLUKE 9132/9133 Portable Infrared Calibrator with Blackbody Source
Product overview: Fluke 9132/9133 Portable Infrared Calibrator with Blackbody Source
Reliable, Portable Blackbody Calibration for IR Thermometers and Imagers
Fluke’s 9132 and 9133 infrared calibrators are designed to meet the precise needs of infrared thermometer and thermal imager users. These portable blackbody sources offer fast heating and cooling, stable temperatures, and radiometric accuracy—making them ideal for field and lab environments alike.
Fluke 9132 – High-Temperature Blackbody Source (Up to 500 °C)
- Designed for IR calibrations above ambient
- Provides a stable blackbody surface up to 500 °C (932 °F)
- Short heating and cooling times keep workflows efficient
- Radiometric calibration ensures measurement confidence across its entire range
Fluke 9133 – Low-Temperature Blackbody Source (–30 °C to 150 °C)
- Ideal for calibrating IR thermometers at low temperatures
- Reaches –30 °C (22 °F) in typical ambient conditions using solid-state cooling
- Convenient dry gas fitting on front bezel prevents ice buildup on the target
- Offers stable temperature control up to 160 °C (320 °F)
- Heats or cools from ambient to either extreme in approximately 15 minutes
What is a Blackbody Calibrator?
A blackbody calibrator (or blackbody source) is a device that emits thermal radiation with high emissivity, typically near 1.0. This makes it behave closely to an ideal blackbody, emitting radiation according to Planck’s law.
Blackbody calibrators are essential tools for ensuring the accuracy of:
- Infrared thermometers
- Thermal imagers
- Non-contact temperature measurement devices
By aiming a device under test at the precisely controlled blackbody target, users can verify and adjust readings to ensure accuracy and compliance with calibration standards.
Summary: Why Choose the 9132 or 9133?
Model Temperature Range Ideal For 9132 Up to 500 °C (932 °F) High-temperature IR calibration 9133 –30 °C to 160 °C (–22 °F to 320 °F) Low-temperature IR calibration with fast transitions Both units provide:
- Portable, stable blackbody sources
- Quick heating and cooling times
- High emissivity targets for accurate infrared calibration
- Confidence backed by Fluke’s precision and reliability
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 9103/9140 Field Dry-Well
Portable, fast, and accurate temperature sources for on-site calibration
Exceptional Performance in a Compact Design
The Fluke 9103 and 9140 Field Dry-Wells outperform the competition in nearly every category—performance, size, weight, ease of use, calibration simplicity, software integration, and price.
Each unit features:
- Adjustable heating and cooling rates via the front panel
- Thermal switch actuation testing
- Multiple-hole inserts for compatibility with a wide range of probe sizes
Fast Calibration with Minimal Downtime
- Units are easy to calibrate without opening the case, reducing maintenance costs and downtime
- All units include a NIST-traceable calibration certificate at no additional charge
- Factory-tested for accuracy and reliability before shipment
Software Integration
Fluke’s Interface-it software supports:
- Set-point and ramp rate control
- Real-time temperature logging
- Electronic strip chart creation
- Thermal switch test automation with data collection
- Windows-based interface with intuitive graphical controls
Whether you need basic control or full automation, Fluke has a software solution ready.
Fluke 9103 – Low-Temperature Field Dry-Well
- Temperature Range: Down to –25 °C (actual, not below ambient)
- Stability: ±0.02 °C
- Display Accuracy: ±0.25 °C across full range
- Speed:
- Reaches 0 °C in 8 minutes
- Reaches 100 °C in 6 minutes
Key Advantage:
Many competitors advertise –45 °C below ambient, which only reaches around –20 °C. The 9103 delivers a true –25 °C in standard room conditions—no walk-in freezer required.
Insert Options:
Choose from four removable inserts to suit your calibration needs:
- Insert A: One well each from 1/16” to 1/2”
- Insert B: Two wells each of 3/8”, 1/4”, and 3/16” (ideal for comparison calibrations)
- Insert C: Six 1/4” wells for multiple probe calibrations
- Insert D: Three pairs of metric-sized wells
Fluke 9140 – Mid-Temperature Field Dry-Well
- Temperature Range: 35 °C to 350 °C
- Stability: ±0.05 °C or better
- Uniformity:
- 0.1 °C in small-diameter wells
- 0.4 °C in largest-diameter wells
- Speed: Reaches max temperature in 12 minutes
- Size: Weighs only 6 lbs, easily portable with one hand
- Display Accuracy: ±0.5 °C
For improved calibration accuracy, use an external thermometer alongside the built-in display.
Insert Options:
Three removable inserts available to accommodate various probe sizes.
Why Choose the 9103 or 9140?
Model Temperature Range Stability Display Accuracy Key Benefits 9103 –25 °C to 110+ °C ±0.02 °C ±0.25 °C True sub-ambient performance without freezer 9140 35 °C to 350 °C ±0.05 °C ±0.5 °C Light, fast, and ideal for field portability Both models are:
- Reliable for industrial and lab environments
- Versatile with multiple insert options
- Backed by Fluke’s proven calibration technology
(0 reviews)