FLUKE 718 Pressure Calibrator
- Pressure Source and mA Measurement to calibrate pressure devices
- Built-in pump for sourcing pressure to 300 PSI
- Easy-to-clean, field-serviceable, integrated pressure pump
- Built-in switch test for calibrating pressure switches
- Extend pressure capabilities by using Fluke 750P pressure modules
Related products
-
Pressure Calibrators
FLUKE Calibration E-DWT Electronic Deadweight Tester
A modern alternative to the traditional deadweight tester
E-DWT-H breaks new ground, improving the hydraulic pressure calibration process. E-DWT-H is an electronic calibrator designed to replace mechanical, piston-cylinder and weight based deadweight testers. It’s a lighter, easier-to-use deadweight tester alternative that is at home in the lab or instrument shop, as well as in the field performing in-situ calibrations and tests. This complete hydraulic pressure calibration system combines the convenience and precision of continuous, realtime electronic pressure measurement with the simple and direct operation of high quality operator controlled pressure generation hardware. E-DWT-H one year measurement uncertainty is ±0.02% of reading with ranges up to 30,000 psi. It can be configured to provide this uncertainty from its full scale down to 1% of its range. Built-in pressure generation and control hardware allow the operator to fill and prime the system under test and generate and precisely adjust pressure throughout the range with ease.
Broad workload coverage
The E-DWT-H has the operational versatility to calibrate and test a broad range of pressure measuring instruments including:
- Analog gauges
- Transducers
- Calibrators
- Sensors
- Transmitters
AutoTest™ lets E-DWT operators quickly define test points and adjust all of the range-dependent settings with a single function.
The resolution and stability test used by the RPM4-E-DWT are set according to the range of the device under test. The upper limit setting is also set and provides range-based warnings and overpressure protection. While running AutoTests, the operator is prompted to set each sequential test point and test data is stored in the RPM4-E-DWT for recall or download. Typical test setup is quick and easy, but more complex tests can also be stored and reused.
Deadweight tester performance with digital measurement convenience
E-DWT-H offers precision, low measurement uncertainty and the stability over time of a conventional deadweight tester without the inconveniences associated with the piston-cylinders, weights, hand pumps, and interconnecting plumbing.
- No weights to load and unload or regularly send out for calibration
- No need to know and correct for local gravity or ambient temperature
- No piston-cylinder changes; switch Q-RPT ranges in seconds
- Not sensitive to level or vibration
- Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses
- Operates in any unit of measure while deadweight tester is typically limited to the pressure unit stamped on the mass
- Perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
- On-board, AutoTest calibration routines and data acquisition
- Interfaceable with a PC or laptop to allow for automated data acquisition
- Two year calibration interval supported at measurement uncertainty of ±0.025% of reading.
- Easily recalibrated without crossfloating. Automated calibration of E-DWT-H is possible using COMPASS® for Pressure software.
Versatility to cover a broad workload in a variety of environments
The E-DWT-H is at home in metrology and calibration labs, on the production floor or in the field. It operates with Sebacate calibration fluid, mineral oil, Skydrol® and other liquids. An optional battery/charger pack supports up to eight hours of operation away from line power.
(0 reviews) -
Pressure Calibrators
FLUKE 750P Series Pressure Modules
Fluke 750P Series Pressure Modules will turn your Fluke multifunction calibrator into a full-fledged pressure calibrator. These flexible modules not only work with multifunction calibrators like the 725, 726 or 750 Series Calibrators but also extend the measurement range of Fluke pressure calibrators. Since the pressure modules are calibrated independently, they can be swapped from one calibrator to another without a loss of accuracy or traceability.
Measuring pressure with Fluke 750P Series Pressure modules is as easy as connecting the module to a pressure source or hand pump, connecting the pressure module cable to the calibrator and then applying pressure from the pressure source. At the touch of a button the measured pressure is displayed digitally on the calibrator in up to 11 different engineering units quickly giving you the data you need. And, with “no tools required” connectors you don’t even need to reach for a wrench to make connections.
When used with the 750 Series Documenting Process Calibrators pressure readings can even be date/time stamped and stored in documented calibration records for later retrieval. This saves time, eliminates errors, and supports compliance with quality standards and regulations.
A complete family of pressure modules
With over 50 pressure modules covering pressure calibration and measurement workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar) finding a model to meet the needs of your specific application is easier than ever. All modules include NPT, metric (BSP) and M20 adapters.
Choose from:
- Differential modules
- Gage modules
- High pressure modules
- Absolute modules
- Vacuum modules
- Dual range modules
- Reference modules
- Intrinsically safe modules
With more than 50 pressure modules to choose from, some of the more popular modules include:
- Fluke 750P00
- Fluke 750P02
- Fluke 750PD2
- Fluke 750P03
- Fluke 750P05
- Fluke 750P06
- Fluke 750P29
Click the Models tab above for a full list of pressure modules.
Designed to go where you work
Pressure instruments are often installed in harsh, hard to reach locations, so you need test tools that handle rough service. 750P Series Pressure Modules feature a rugged protective boot that guards the module against shock and seals against dirt and dust, if you accidently drop them, there’s no need to worry. The 750P series modules are also specified across a broad temperature range. Though more accurate across a narrower temperature range if used indoors, these modules are designed and specified to deliver traceable pressure measurements in environments from -10 °C to +50 °C.
(0 reviews) -
Pressure Calibrators
FLUKE 718Ex Intrinsically Safe Pressure Calibrator
- ATEX II 1G Ex ia IIC T4 Compliant.
- Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.
- 30, 100, and 300 psi ranges (2, 7, and 20 bar)
- Pressure measurement to 0.05% of full span, using an internal pressure sensor.
- Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
- Wide range of selectable measurement units for pressure.
- Current measurement with 0.02% accuracy and 0.001 mA resolution.
- Pressure switch test function.
- Min-Max Hold functions.
- Compact size and weight.
- Simple, push-button user interface.
- Rugged and reliable, ideal for field use.
(0 reviews) -
Pressure Calibrators
FLUKE 730G Digital Pressure Calibrator
- Pressure measurement from ±10 inH2O/2.5 kPa to 10000 psi/69 MPa
- Four absolute pressure measurement ranges: 15 PSIA (103 kPa), 30 PSIA (207 kPa), 100 PSIA (690 kPa), 300 PSIA (2 MPa)
- Pressure measurement accuracy 0.05% of full scale, 0.02% optional
- Current measurement range: 0-24mA
- Voltage measurement range: 0-30VDC
- 0.01% current and voltage accuracy
- Powerful HART communication, supports HART 7
- 24V loop power, no external power supply needed
- Lithium battery life: 25 hours continuously (without 24 V loop power), or 8 hours continuously (24 V loop power)
- Storage up to 128 sets of calibration data
- Ingress protection: IP54
- 1-meter drop test
- Three-year warranty
(0 reviews)