FLUKE 1586A Super-DAQ Precision Temperature Scanner
- Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance, with up to 40 isolated universal inputs.
- Precision measurements (PRTs ± 0.005 °C, thermocouples: ± 0.5 °C, thermistors: ± 0.002 °C).
- Scan up to 10 channels per second, great for high-speed applications.
- Four operation modes – Scan, Monitor, Measure, Digital Multimeter (DMM), and features real-time color trending for up to four channels.
- Records up to 20 MB of data and setup files to internal non-volatile memory or an external USB drive, with administrator and user profiles for data protection and test traceability.
Related products
-
Temperature Calibrators
FLUKE 9132/9133 Portable Infrared Calibrator with Blackbody Source
Product overview: Fluke 9132/9133 Portable Infrared Calibrator with Blackbody Source
Reliable, Portable Blackbody Calibration for IR Thermometers and Imagers
Fluke’s 9132 and 9133 infrared calibrators are designed to meet the precise needs of infrared thermometer and thermal imager users. These portable blackbody sources offer fast heating and cooling, stable temperatures, and radiometric accuracy—making them ideal for field and lab environments alike.
Fluke 9132 – High-Temperature Blackbody Source (Up to 500 °C)
- Designed for IR calibrations above ambient
- Provides a stable blackbody surface up to 500 °C (932 °F)
- Short heating and cooling times keep workflows efficient
- Radiometric calibration ensures measurement confidence across its entire range
Fluke 9133 – Low-Temperature Blackbody Source (–30 °C to 150 °C)
- Ideal for calibrating IR thermometers at low temperatures
- Reaches –30 °C (22 °F) in typical ambient conditions using solid-state cooling
- Convenient dry gas fitting on front bezel prevents ice buildup on the target
- Offers stable temperature control up to 160 °C (320 °F)
- Heats or cools from ambient to either extreme in approximately 15 minutes
What is a Blackbody Calibrator?
A blackbody calibrator (or blackbody source) is a device that emits thermal radiation with high emissivity, typically near 1.0. This makes it behave closely to an ideal blackbody, emitting radiation according to Planck’s law.
Blackbody calibrators are essential tools for ensuring the accuracy of:
- Infrared thermometers
- Thermal imagers
- Non-contact temperature measurement devices
By aiming a device under test at the precisely controlled blackbody target, users can verify and adjust readings to ensure accuracy and compliance with calibration standards.
Summary: Why Choose the 9132 or 9133?
Model Temperature Range Ideal For 9132 Up to 500 °C (932 °F) High-temperature IR calibration 9133 –30 °C to 160 °C (–22 °F to 320 °F) Low-temperature IR calibration with fast transitions Both units provide:
- Portable, stable blackbody sources
- Quick heating and cooling times
- High emissivity targets for accurate infrared calibration
- Confidence backed by Fluke’s precision and reliability
(0 reviews) -
Multifunction Calibrators
FLUKE 753 Documenting Process Calibrator
Fluke 753 Documenting Process Calibrator helps you work smarter and faster
The Fluke 753 is a powerful multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software, and upload data for printing, archiving, and analysis. You’ll find it does the work of several tools, with simultaneous source and measurement capabilities for all common process parameters. It sources, simulates, and measures pressure, temperature, and electrical signals in one rugged, hand-held calibration tool. It also automates calibration procedures, captures data for documentation, and helps you meet rigorous standards like ISO 9000, FDA, EPA, and OSHA regulations.
The 753 includes a USB interface and a USB communication cable to enable two-way communication with DPCTrack 2 and other instrumentation management applications. To create a seamless/paperless calibration management system consider adding Fluke DPCTrack2 Calibration Management software for use with your Fluke 753 and 754 or even legacy Fluke 743 and 744 calibrators.
Other useful features:
- Measures and sources pressure using any of 50 Fluke 700Pxx Pressure Modules
- Allows you to creates and run automated as-found/as-left procedures to satisfy quality programs or regulations, and record and document results
- Holds up to a full week of downloaded procedures and calibration results
- Offers many flexible features like autostep, custom units, user-entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more.
- Offers compatibility with DPCTrack2 and many other asset management software packages
- Bright white dual display for reading both sourced and measured parameters simultaneously
- Easy-to-use multi-lingual interface
- Gas gauge and rechargeable Li-Ion battery for 10 hour uninterrupted use
- Comes with three-year warranty and DPC/Track trial software
(0 reviews) -
Temperature Calibrators
FLUKE Full Immersion PRT
Ultra-Compact, Reliable, and Designed for Complete Immersion
Total Flexibility for Extreme Environments
The Fluke 5606 Full Immersion Platinum Resistance Thermometer (PRT) offers an unmatched solution for applications where full immersion of the probe—including transition junction and lead wires—is required. With a compact length of just two inches (50 mm) and a sheath diameter of only 1/8 inch (3.1 mm), the 5606 delivers accuracy and durability in the tightest spaces.
Key Features and Benefits
- Truly Full Immersion – No need to calculate minimum immersion depth. Simply immerse the entire probe, transition junction, and lead wires over the entire operating range—from –200 °C to 160 °C—in either non-corrosive liquids or dry mediums.
- High Accuracy in a Compact Size – Achieve calibration accuracies as good as ±0.05 °C, thanks to the specially constructed 100 Ω precision sensing element (alpha = 0.00385) that also blocks moisture ingress.
- Superior Moisture Protection – Single-conductor enameled copper lead wires prevent moisture from wicking into the sensing element, offering better protection than traditional stranded leads.
- Flexible and Easy Installation – Lead wires measure no greater than 0.2 mm in diameter, making it simple to route through tight spaces—such as a freezer door—without energy loss.
- Proven Durability – The 5606 has demonstrated excellent performance in heat transfer fluids like silicone oil, mineral oil, ethanol, and even liquid nitrogen, with no loss of integrity in the transition junction or lead wire insulation.
Engineered for Demanding Applications
The 5606 Full Immersion PRT is specifically designed to thrive in extreme environments. Both the transition junction and lead wires are built to endure temperatures covering the full probe range, ensuring complete reliability in challenging conditions.
“Immersion” means exposure to extreme temperatures—not just being submerged in a liquid—making the 5606 ideal for a wide variety of rigorous uses.
(0 reviews) -
Temperature Calibrators
FLUKE Calibration 1502A/1504 Thermometer Readout
Precision thermometer readouts for laboratory and field use
1502A Tweener PRT Readout
The Fluke Calibration 1502A Tweener offers precision temperature measurement with:
- Accuracy up to ±0.006 °C
- Resolution of 0.001 °C across the entire range
- Compatibility with 100-ohm, 25-ohm, and 10-ohm RTD probes
- Smallest unit in its class, ideal for field or bench use
- Optional 9320A Battery Pack for full portability
Advanced Features
- Programmable to match a probe’s constants for maximum linearity and accuracy
- Displays temperature in °C, °F, K, or resistance in ohms
- Reads standard industrial IEC-751 / “385 ALPHA” RTDs with no programming required
- Accepts ITS-90 subranges 4 and 6–11, with formulas built into firmware
- Calibration is done digitally via front-panel—no need to open the device
- Comes with RS-232 interface; optional IEEE-488 interface available
1504 Tweener Thermistor Readout
Need higher precision in a narrower temperature range? The Model 1504 Tweener offers:
- Accuracy up to ±0.002 °C
- Resolution of 0.0001 °C
- Designed specifically for thermistors—more robust, shock-resistant sensors with faster response times
- Ideal for applications requiring high sensitivity and reliability in limited temperature spans
Calibration and Probe Integration
- Each Tweener and its compatible probe (sold separately) include individual calibration reports
- System data is available upon request at two or more temperatures for high-precision needs (Calibration Model 1929-X)
- Users can calculate system accuracy using individual device specifications—no need to purchase system-level data unless required
Software Compatibility
Enhance your workflow with Fluke software tools:
- 9934 LogWare: Real-time data acquisition, graphing, and analysis
- MET/TEMP II: Use Tweeners as reference thermometers for automated calibrations
Optional Battery Pack
Take your Tweener on the road with the 9320A Battery Pack:
- Provides up to 36 hours of portable operation between charges
- Perfect for fieldwork or locations without direct power access